Operation Manual
Version 2.0
13
Part Number MAN-000009
Setup Parameters
Follow the system wiring diagram (
) to aid in the installation process, including supplied relays and switches.
Once installation is completed, the BinTrac Breeder Control unit must be programmed as summarized below:
1. The BinTrac Breeder Control console controls the batching from the inventory bin into the weigh bin (
steps 1
through 19
).
Access SETUP mode and configure the following:
•
Set the Batch type to Load Batching
•
Set an
L.C.CAP
value that matches the total capacity of all load cells
•
Set a
FuLL
value that matches the maximum capacity of the weigh bin
•
Set the
Hour
time parameter (default is CST Zone)
System Settings in Setup Mode
The SETUP mode is used to configure the one-time system setup settings for the appropriate
configuration. The following SETUP parameters MUST be correctly configured to ensure proper
operation and weighing:
•
BATCH
•
L.C.CAP
•
FULL
•
ZERO
•
HOUR
NOTE
: When first powering on the unit,
.
will be displayed. This is simply a reminder that
the load cell capacity for the system must be entered in the SETUP menu to ensure proper weighing
calibration.
NOTE
: If there is no activity for a period of time while in SETUP mode, the system will exit and return
to the Weight Display mode.
Navigating Setup Mode
To navigate through the options in SETUP mode, use the
and
keys to cycle through the
options/parameters. See the SETUP menu flow chart to the right.
Accessing the Setup Mode
1. Press and hold the SELECT button down until
is displayed.
Segmented display:
2. Press the
key and
will be displayed.
SETUP Menu
Flow Chart
Summary of Contents for BinTrac Breeder Control
Page 18: ...Operation Manual Version 2 0 18 Part Number MAN 000009 Wiring Diagram...
Page 25: ...Operation Manual Version 2 0 25 Part Number MAN 000009 Wiring Diagram OPTIONAL...
Page 36: ...Operation Manual Version 2 0 36 Part Number MAN 000009 Wiring Diagram...
Page 47: ...Operation Manual Version 2 0 47 Part Number MAN 000009 Wiring Diagram...