Photocell=OK
Emergency stop=OK
Open inlet=Not affected
Control box=Closed
Open signal=OK
Power supply=OK
Open pulse GSM=Off
-=-
filter time for the input in question has run out.
??
STATUS
In1=1
In2=0
In3=0
In4=1
In5=1
In6=0
In7=1
In8=0
R1=OFF
R2=OFF
Ext power=ON
Signal=15 (31)
SW=X.XX
The reply shows the input and output logical levels, as well as
the status of the power supply.
The signal strength has a value between 0 and 31, where 31
is the best signal strength. For reliable functioning, the signal
strength should be above 14.
SW shows which software version the device features.
Filtered values are shown, change is first made when the
filter time for the input in question has run out.
R1=ON
R2=ON
None
The notification activates relay 1 (R1) or relay 2 (R2), which
creates a connection at the relay output.
R1=OFF
R2=OFF
None
The notification activates relay 1 (R1) or relay 2 (R2), which
breaks the connection at the relay output.
R1=60
R2=60
None
The notification activates relay 1 (R1) or relay 2 (R2) in 60
seconds.
Time can be stated between 1 and 65,000 seconds