Model OFG- 390
2-7. GAS LEAK TEST
Prior to turning the gas supply on, be sure the gas valve
knob on the gas control valve is in the OFF position.
The word “OFF” is at the bottom of the knob when the
valve is closed.
Upon initial installation and after moving the unit, the pipings and
fittings should be checked for gas leaks. A simple checking method
is to turn on the gas and brush all connections with a soap solution.
If bubbles and occur, it indicates escaping gas. In this event, the
piping connection must be redone.
To avoid fire or explosion, never use a lighted match
or open flame to test for gas leaks. Ignited gas could
result in severe personal injury and/or property
damage.
2-8. GAS PRESSURE
The gas pressure regulator on the gas control valve is
REGULATOR SETTING
factory set as follows:
Natural: 3.5 inches water column (.87 kPa)
Propane: 10.0 inches water column (2.49 kPa)
The gas pressure regulator has been set by Henny Penny and
is not to be adjusted by the user.
MAKE SURE GAS PRESSURE IS SET COR-
RECTLY. FAILURE TO DO SO CAN RESULT IN
SHORTENING OVERFLOWING THE FRYPOT,
WHICH COULD CAUSE SERIOUS BURNS,
PERSONAL INJURY, FIRE AND/OR PROPERTY
DAMAGE.
703
2-9
Summary of Contents for OFG-390
Page 1: ...OPERATOR S MANUAL Henny Penny Open Fryer Model OFG 390 ...
Page 2: ......
Page 10: ......
Page 13: ...Model OFG 390 OptionalRampUnloading 703 2 3 ...
Page 14: ...Model OFG 390 2 4 908 ...
Page 18: ...Model OFG 390 2 8 303 ...
Page 22: ......