![Henny Penny EEG-16X Operator'S Manual Download Page 91](http://html1.mh-extra.com/html/henny-penny/eeg-16x/eeg-16x_operators-manual_2124320091.webp)
81
Display
Cause
Panel Board Correction
“E-60”
“FILTER IN
USE”
AIF PC board not
communicating
with PC board.
Turn power switch to OFF, wait 15 seconds, then turn
switch back to ON. If “E-60 persists, have connector be-
tween the PC boards checked; replace AIF PC board or
control PC board if necessary.
“E-70C”
Drain valve jump-
er wire missing or
disconnected.
Have the jumper wire checked on the PC board at drain
switch interlock position.
“E-83-A”
Pressure too
high.
Check filter system in Vat #1.
“E-83-B”
Pressure too
high.
Check filter system in Vat #2.
“E-83-C”
Pressure too high
Check filter system in Vat #3.
“E-83-D”
Pressure too
high.
Check filter system in Vat #4
“E-83-E”
Pressure too
high.
Check filter system in Vat #5.
“E-83-J”
Bulk BIB FILL
switch ON when
pressure too
high.
Check BIB fill valves.
“E-83-R”
Bulk Dispose
switch ON when
pressure too
high.
Check Bulk Dispose quick-disconnect behind fryer.
“E-931”
”24 VDC
SUPPLY
TRIPPED”
Autolift motor
malfunction or
failure.
If AutoLift feature is not operating, have each of the Auto-
lift motors checked.
Summary of Contents for EEG-16X
Page 2: ......
Page 10: ...Preface viii...
Page 12: ...Introduction 2...
Page 22: ...Installation 12 Figure 2 3 2 Well Dimensions Figure 2 4 3 Well Dimensions...
Page 23: ...Installation 13 Figure 2 5 4 Well Dimensions...
Page 24: ...Installation 14...
Page 66: ...Operation 56...
Page 72: ...Information Mode 62...
Page 76: ...Product Program Mode 66...
Page 92: ...Troubleshooting 82...
Page 93: ...blank page...