![Henny Penny EEG-16X Operator'S Manual Download Page 33](http://html1.mh-extra.com/html/henny-penny/eeg-16x/eeg-16x_operators-manual_2124320033.webp)
23
NOTE: To stop a cook cycle at any time, press and hold timer button 1
or 2
.
3
3..6
6 IId
dlle
e M
Mo
od
de
e
Once programmed, Idle Mode help saves on oil and utility costs by lowering set-point
of oil when vat is not being used. To activate Idle Mode, press product button 0
, or
can be programmed to activate automatically after “X” minutes of inactivity on the vat.
The oil is maintained at a lower temperature until product button 2
is pressed,
and then the oil is heated to cooking temperature. See Special Program Modes SP-7,
SP-7A, SP-7B, & SP-7C.
3
3..7
7 O
Oiill G
Gu
ua
arrd
diia
an
n™
™ ((A
Au
utto
o T
To
op
p--O
Offff))
During normal operation, the control automatically monitors vat oil level. If the control
senses oil level is too low, unit automatically pumps oil from BIB into vat to keep oil at
the proper level.
3
3..7
7..1
1 M
Ma
an
nu
ua
all T
To
op
p--O
Offff
If oil level is a little low, oil can be added to vat at any time from BIB to raise oil level to
the proper level by following steps below. This procedure is NOT to be used to fill an
empty vat.
1
1))
Press and hold filter button
(full vat- either one) until display shows “*FILTER
MENU*” followed by “1.EXPRESS FILTER”.
2
2))
Press the right arrow button 5 times until “6.FILL FORM BIB” shows in display.
3
3))
Press “✓” button, “FILL VAT” “✓=PUMP” “X=DONE” is displayed.
4
4))
Press and hold “✓” button, display shows “FILLING” and oil is pumped from the
BIB to the vat.
5
5))
Once vat is full, release “✓” button, “FILL VAT” “✓=PUMP” “X=DONE” displays.
Press “X” button twice for normal operation.
3
3..8
8 S
Se
elle
eccttiin
ng
g P
Prro
od
du
ucctt W
Wiitth
h A
A D
Diiffffe
erre
en
ntt S
Se
ett--P
Po
oiin
ntt
When selecting a product, if “XXX XXX” shows in display, the setpoint temperature is
not correct for this product. To change the setpoint temperature for the desired
product:
1
1))
Press product button, for ex: product button 1
(FRY).
2
2))
Display shows “XXX XXX”.
Summary of Contents for EEG-16X
Page 2: ......
Page 10: ...Preface viii...
Page 12: ...Introduction 2...
Page 22: ...Installation 12 Figure 2 3 2 Well Dimensions Figure 2 4 3 Well Dimensions...
Page 23: ...Installation 13 Figure 2 5 4 Well Dimensions...
Page 24: ...Installation 14...
Page 66: ...Operation 56...
Page 72: ...Information Mode 62...
Page 76: ...Product Program Mode 66...
Page 92: ...Troubleshooting 82...
Page 93: ...blank page...