![Henny Penny EEG-16X Operator'S Manual Download Page 78](http://html1.mh-extra.com/html/henny-penny/eeg-16x/eeg-16x_operators-manual_2124320078.webp)
68
Program Code
Description
SP-7
Idle Mode Enabled - YES or NO
SP-7A
Use “0” for IDLE
SP-7B
Auto Idle Minutes
SP-7C
Idle Set-Point Temperature
SP-8
Filter Tracking Mode - 1.MIXED or 2.GLOBAL
SP-8A
Suggest Filter At... - 75% to 100% (MIXED)
SP-8B
Filter Lockout Enabled? - YES or NO (MIXED)
SP-8A
Left Vat Filter Cycles - 0 to 99 (GLOBAL)
SP-8B
Right Vat Filter Cycles - 0 to 99 (GLOBAL)
SP-8C
Filter Lockout Enabled? - YES or NO (GLOBAL)
SP-9
Polish Time Duration - X:XX M:SS
SP-10
Change Pad Reminder Time - XX HRS
SP-11
Clean-Out Time - XX MIN
SP-12
Clean-Out Temperature - XXX °F or °C
SP-13
Cooking User IO - After Cook Cycle, display shows previous menu
item or “——”
SP-14
Number of Baskets - 2-BASKETS or 4-BASKETS
SP-15
Show Cooking Indicator - YES or NO
SP-16
2nd Language: English, Greek “EΛΛHNIKA”, Russian “РУССКИИ”,
Swedish “SVENSKA”, German “DEUTSCHE”, Portuguese “POR-
TUG.”, Spanish “ESPANOL”, or French “FRANCAIS”.
SP-17
2nd Audio Volume
SP-18
Energy Save Enabled? - YES or NO
SP-19
Fryer Type - GAS or ELECTRIC
SP-20
Vat Type - SPLIT or FULL
SP-21
Autolift Enabled? - NO LIFT or YES LIFT
SP-22
Bulk Oil Supply? - YES SUPL or NO SUPL
SP-23
Direct Oil Dispose? - YES DISP or NO DISP
SP-24
Serial No. of Fryer
SP-25
Change Mgr. Code- 1 = YES
SP-26
Change Usage Code - 1 = YES
Summary of Contents for EEG-16X
Page 2: ......
Page 10: ...Preface viii...
Page 12: ...Introduction 2...
Page 22: ...Installation 12 Figure 2 3 2 Well Dimensions Figure 2 4 3 Well Dimensions...
Page 23: ...Installation 13 Figure 2 5 4 Well Dimensions...
Page 24: ...Installation 14...
Page 66: ...Operation 56...
Page 72: ...Information Mode 62...
Page 76: ...Product Program Mode 66...
Page 92: ...Troubleshooting 82...
Page 93: ...blank page...