1.
Fit the correct plug on the cable in accordance with local legislation and connection data. See
Technical Data on page 66 for the correct electrical connection.
2.
Connect the machine to a grounded wall outlet to avoid fire or electric shock.
•
The power cable must be free at all times, and nothing may be placed on it.
•
Immediately replace the power cable if damaged.
3.
Operating the machine with an incorrect direction of rotation results in damage to the pump,
in which case no vacuum can be created. After connecting the machine to a different three-
phase power supply, the direction of rotation should be checked again. If the direction of
rotation is incorrect, two phases in the plug must be interchanged.
Figure 3: Direction of Rotation of the Vacuum Pump
4.
Optional: Connect the gas supply for the gas flush system.
5.
Optional: Connect the air supply for additional sealing pressure.
5.3 Prior to the First Use
See Vacuum Pump maintenance on page 59 for more information how to perform these steps.
Prior to the first use, the following steps must be performed:
Failure to do so may result in unrepairable damage to the machine.
1.
Check the oil sight glass to see if the amount of oil in the pump is sufficient.
2.
Optional: If the amount of oil in the pump is insufficient, refill it.
3.
Start up the machine. See Operation on page 23 for more information.