- Adding Transmitters

To add extra transmitters
Press the operating button for 5 seconds and release when the red LED indicator goes out. The LED will flash once to confirm Add
Mode.Take the new transmitter to be added and press the button once.The red LED indicator should flash once. Repeat this for every
new transmitter to be added to the system. After the last transmitter has been added either wait 30 seconds or press the operating
push button once to reset to normal operation.
The remote control system uses the latest “rolling code” technology. Hand transmitters supplied are pre-programmed.The receiver can
memorise the codes of 15 transmitters. Upgrade memory chips are available for 31 or 62 transmitters by special order.

- Deleting Transmitters

It is not possible to selectively delete transmitters and selecting delete mode will erase all transmitters from the system. Switch off the
power supply to the unit and remove the front cover.Turn on Dip switch 5 and re-power the unit.The circuit board mounted yellow
“set radio” LED will illuminate for 5 seconds, all transmitters are now deleted. Switch off the power supply , turn off Dip switch 5 and
re-fit the front cover.Transmitters can now be reloaded using the “Add Transmitters“ procedure.

10 

- Dip Switch Settings

The  RS1 control unit has five onboard Dip switches which control the following features.

10.1  Dip switch 1 warning. When switched on, the courtesy light will flash three times before the door moves.
10.2  Dip switch 2 Retract. When switched on, selects partial retract. If the photocell is activated the door retracts 200mm instead of
returning to the fully open position.
10.3  Dip switch 3 Security. When switched on, extends the motor supply feed for the duration of the motor run timer which assists
adjustment of screw type motor limit switches Dip switch 3 is normally turned off. Additionally for doors having an externally fitted
manual override system, switching on Dip switch 3 selects a security system. If the manual override system is used to force open the
door, the system will power down the door to the closed position.
Note- When using the security system it is important to accurately set the motor run timer. operate the door from the fully closed to
the fully open position and adjust the run timer so that the circuit board “open” LED goes out five seconds after the door arrives at the
fully open position. See Fig 9.
10.4  Dip switch 4  Auto- Close. This option is normally turned off. Turning on Dip switch 4 selects an automatic time delay self
closing function.The time delay begins when the door is fully open and is reset if the photoelectric safety beam is broken.The auto-close
delay is dependant upon door size and operating speed. Set the motor run timer as described in “security”, the corresponding auto close
delay is shown in Fig 9.
Note ; Selecting Auto-close increases the level of automation and to comply with relevant safety standards we recommend the installation
of additional safety devices ie, safety edge system or additional photoelectric sensor.
10.5  Dip switch 5 Decode
Used when removing lost or stolen transmitters from the receiver memory. [see 9 Deleting Transmitters.]

Figure 9 - Run Timer Settings

Summary of Contents for Ansa RS1

Page 1: ...are suitable for the application and are all working satisfactorily This will permit the nominated person to attach a CE label identifying the name of the installing company a unique door reference nu...

Page 2: ...Installation Instructions Insulated roller door and Compact insulated roller door remote control unit March 2007 Insulated Roller Garage Doors...

Page 3: ...e read these instructions carefully prior to commencing installation of the unit Operate unit only when the door is in full view and free from any obstruction No one should enter or leave the garage w...

Page 4: ...lectronics monitor the motor drive and limit switches and turn off the motor run timer as soon the door reaches a fully open or a fully closed position There is no need to wait for the run time to exp...

Page 5: ...s are used they should be the same type OPERATION The safety beam has no effect on an opening door Breaking the safety beam prevents closure of an open door and will also stop and re open a closing do...

Page 6: ...close circuit board LED S if necessary switch off the mains power supply and interchange the motor cables at L1 and L2 Note the motor unit has an inbuilt thermal trip which activates if the motor get...

Page 7: ...Figure 6 Connection diagram Installing 2 photoelectric cell units Figure 7 Connection diagram Option controls...

Page 8: ...important that the photo beam is centred on the reflector using the following set up procedure Adjust fixing screws A B so that the photoelectric sensor and pivot bracket can be moved up and down and...

Page 9: ...en switched on selects partial retract If the photocell is activated the door retracts 200mm instead of returning to the fully open position 10 3 Dip switch 3 Security When switched on extends the mot...

Page 10: ...ig 3 In some instances it may be helpful to switch off the controls operating the door temporarily without turning off the mains power supply or erasing transmitter security codes For example during h...

Page 11: ...nk wire interconnecting terminals Com Stp if fitted If a stop control device is fitted check the operation and condition of cables connecting this to terminals Com Stp 17 3 Faulty operation the Red in...

Page 12: ...e Engineer Comments Technical Specification 18 SupplyVoltage 220 240VAC Transformer Power 3VA Power Relays 12 A 230VAC OperatingTemperature 15 to 55 deg C Enclosure Rating IP 44 Courtesy light 40 watt...

Reviews: