Henderson Ansa RS1 Installation Instructions Manual Download Page 8

Fit the Photoelectric Safety Sensor - 

7

Refer to figure 8.
Fix the photo cell brackets to the door guides at a recommended height of 300mm using the self-drilling screws provided. Fit the photoelectric
sensor to the pivot bracket using 2No M3 x 25mm nuts and bolts provided ensuring that the flat and shake proof washers are correctly fitted.
Attach the pivot bracket to the photocell bracket using 2No M4 x 15mm nuts and bolts provided. Fit the photocell reflector to the opposite bracket
using 2 No M4 x15mm nuts and bolts provided.

The diagram shows a right hand installation.The photo sensor can be fitted left hand using a similar assembly.

Note: the diagrams show the standard assembly, for extra wide doors, doors fitted with mechanical stops to the bottom rail or doors subject to
high wind pressure it is possible to turn the pivot bracket around which conveniently sets the photoelectric sensor slightly further away from the
door curtain.

7.1  How to align the photoelectric sensor(s) [ Ansa Type MLV 13/54 ]
The green L.E.D is illuminated when the photoelectric cell is switched on. For reliable operation it is important that the photo beam is “centred”
on the reflector using the following set-up procedure:Adjust fixing screws A & B so that the photoelectric sensor and pivot bracket can be moved
up and down and left to right. Move the sensor until the yellow L.E.D illuminates. Carefully move the pivot bracket left and right to obtain reference
points where the yellow L.E.D goes out. Set the pivot bracket in the mid position and tighten screws A.

Now similarly move the sensor up and down again noting the reference points where the yellow L.E.D goes out. Set the sensor in the mid position
and tighten screws B.

With the photocell correctly adjusted and working the green and yellow L.E.D's fitted to the sensor and the red indicator L.E.D fitted to the control
unit will be illuminated. Breaking the photo-beam will switch off the yellow L.E.D fitted to the sensor and cause the red indicator L.E.D to flash
quickly, confirming correct operation.

7.2  Photoelectric Sensor Operation And Testing
The safety beam has no effect on an opening door. Breaking the safety beam prevents closure of an open door and will also stop and re-open a
closing door.

The ADS v1.1 software fitted to the RS 1 control unit continuously monitors the photoelectric sensor. If a fault is detected the system prohibits
closure of the door.

Figure 8 

Summary of Contents for Ansa RS1

Page 1: ...are suitable for the application and are all working satisfactorily This will permit the nominated person to attach a CE label identifying the name of the installing company a unique door reference nu...

Page 2: ...Installation Instructions Insulated roller door and Compact insulated roller door remote control unit March 2007 Insulated Roller Garage Doors...

Page 3: ...e read these instructions carefully prior to commencing installation of the unit Operate unit only when the door is in full view and free from any obstruction No one should enter or leave the garage w...

Page 4: ...lectronics monitor the motor drive and limit switches and turn off the motor run timer as soon the door reaches a fully open or a fully closed position There is no need to wait for the run time to exp...

Page 5: ...s are used they should be the same type OPERATION The safety beam has no effect on an opening door Breaking the safety beam prevents closure of an open door and will also stop and re open a closing do...

Page 6: ...close circuit board LED S if necessary switch off the mains power supply and interchange the motor cables at L1 and L2 Note the motor unit has an inbuilt thermal trip which activates if the motor get...

Page 7: ...Figure 6 Connection diagram Installing 2 photoelectric cell units Figure 7 Connection diagram Option controls...

Page 8: ...important that the photo beam is centred on the reflector using the following set up procedure Adjust fixing screws A B so that the photoelectric sensor and pivot bracket can be moved up and down and...

Page 9: ...en switched on selects partial retract If the photocell is activated the door retracts 200mm instead of returning to the fully open position 10 3 Dip switch 3 Security When switched on extends the mot...

Page 10: ...ig 3 In some instances it may be helpful to switch off the controls operating the door temporarily without turning off the mains power supply or erasing transmitter security codes For example during h...

Page 11: ...nk wire interconnecting terminals Com Stp if fitted If a stop control device is fitted check the operation and condition of cables connecting this to terminals Com Stp 17 3 Faulty operation the Red in...

Page 12: ...e Engineer Comments Technical Specification 18 SupplyVoltage 220 240VAC Transformer Power 3VA Power Relays 12 A 230VAC OperatingTemperature 15 to 55 deg C Enclosure Rating IP 44 Courtesy light 40 watt...

Reviews: