Henderson Ansa RS1 Installation Instructions Manual Download Page 3

Ansa RS1 roller door remote control system

Contents
1

General description

2

Fitting the RS 1 control unit. .

3

Operation

3.2

Function of the red LED indicator.

RS1 Control board- overview.

5

Electrical connections.

6

Commissioning.

7

Fitting photoelectric safety sensor[s]

7.1

How to align the photoelectric beam[s]

7.2

Photoelectric sensor operation and testing

8

Adding transmitters.

9

Deleting transmitters

10

Dip switch Settings

11

Multi- door control

12

Photoelectric Cell Override

13

Fault diagnostic system.

14

Control inhibit feature.

15

Fitting the optional aerial.

16

Maintenance.

17

Problem solving guide

18

Technical specifications

- General Description

- Fitting the RS1 Control Unit

Built-in Light

Multi-function Red LED indicator

Operating button

Lugs

Cover

Spare main
board fuses

Trim

Cover screws

Base

The Ansa RS 1control unit is designed to operate roller garage doors fitted with single phase tubular motor drives. Equipped with “rolling code”
high security remote controls, allowing easy memorisation of up to fifteen transmitters.The unit has all the features needed for efficient, safe and
reliable operation of roller doors including built-on courtesy lamp, operating button and multi- function red indicator LED.

Installation instructions
Please read these instructions carefully prior to commencing installation of the unit. Operate unit only when the door is in full view
and free from any obstruction. No one should enter or leave the garage while the door is in motion.

2.1 The electric drive motor, RS1 control and photoelectric safety
sensor are normally fitted to the same side of the door opening.
Select a suitable position for the control unit, within sight of the door,
well away from moving parts, ensuring that :-

a. It can be plugged into an adjacent 13A switched socket.
b. It is within the constraints of the motor lead, using a 'tidy' cable run.
c. It is mounted with the built on lamp at the top.
d. It is fitted at a height of at least 1.6 metres out of the reach of children.
e. It is fitted inside a dry room only ( I.P.44 rating )

2.2 Fitting the enclosure - Refer to figure 1

Remove the courtesy lamp lens from the base by squeezing the sides
of the lens, disengaging the clip in the top of the lens. Remove any
packaging from the lamp. Pull off the trim, and undo the two fixing
screws approximately 8mm, noting that it is not necessary to
completely remove the screws which remain attached to the cover.
Carefully remove the cover by pulling away from the base with a slight
downward movement. The packing box provides a useful fixing
position guide, Fix the base to the wall using the fixing screws and
plugs provided.

Note: Do not allow dust to enter the unit which could
damage the electronics.

Figure 1

Summary of Contents for Ansa RS1

Page 1: ...are suitable for the application and are all working satisfactorily This will permit the nominated person to attach a CE label identifying the name of the installing company a unique door reference nu...

Page 2: ...Installation Instructions Insulated roller door and Compact insulated roller door remote control unit March 2007 Insulated Roller Garage Doors...

Page 3: ...e read these instructions carefully prior to commencing installation of the unit Operate unit only when the door is in full view and free from any obstruction No one should enter or leave the garage w...

Page 4: ...lectronics monitor the motor drive and limit switches and turn off the motor run timer as soon the door reaches a fully open or a fully closed position There is no need to wait for the run time to exp...

Page 5: ...s are used they should be the same type OPERATION The safety beam has no effect on an opening door Breaking the safety beam prevents closure of an open door and will also stop and re open a closing do...

Page 6: ...close circuit board LED S if necessary switch off the mains power supply and interchange the motor cables at L1 and L2 Note the motor unit has an inbuilt thermal trip which activates if the motor get...

Page 7: ...Figure 6 Connection diagram Installing 2 photoelectric cell units Figure 7 Connection diagram Option controls...

Page 8: ...important that the photo beam is centred on the reflector using the following set up procedure Adjust fixing screws A B so that the photoelectric sensor and pivot bracket can be moved up and down and...

Page 9: ...en switched on selects partial retract If the photocell is activated the door retracts 200mm instead of returning to the fully open position 10 3 Dip switch 3 Security When switched on extends the mot...

Page 10: ...ig 3 In some instances it may be helpful to switch off the controls operating the door temporarily without turning off the mains power supply or erasing transmitter security codes For example during h...

Page 11: ...nk wire interconnecting terminals Com Stp if fitted If a stop control device is fitted check the operation and condition of cables connecting this to terminals Com Stp 17 3 Faulty operation the Red in...

Page 12: ...e Engineer Comments Technical Specification 18 SupplyVoltage 220 240VAC Transformer Power 3VA Power Relays 12 A 230VAC OperatingTemperature 15 to 55 deg C Enclosure Rating IP 44 Courtesy light 40 watt...