Commissioning -
6
6.1
If possible, manually operate the door and position the door curtain half open. Switch on the mains power supply and check that the multi-
function red LED is on.The on board status L.E.D should be illuminated green.
6.3
Adjust the motor limit switches.
Carefully adjust the limit switches following the door manufacturer's instructions. For screw adjuster type limits turn on Dip switch 3. Press the
operating button and ensure that the motor direction matches the open and close circuit board LED'S, if necessary switch off the mains power
supply and interchange the motor cables at L1 and L2.
Note-the motor unit has an inbuilt thermal trip which activates if the motor gets too hot after repetitive use, causing the motor to cut out. If the
thermal trip operates wait approximately 10 minutes for the motor to return to normal operating temperature
When the limit switches are correctly set turn off Dip switch 3 for normal operation.see fig 4
NOTE: Connections shown are for left hand
motor installations. For right hand, swap brown &
black motor cables
Figure 4 - Connection diagram - Set up and testing
Figure 5 - Connection diagram - Remote control with photo cell unit