OPERATING INSTRUCTIONS TREND SERIES
INSTRUMENT POWER AND RELAY WIRING
Trend Loadgard supply wiring connections shall be made with 14 ga. THHN wire or equivalent.
Electrical Specifications
Unit marked for 120V~ operation
120V~ ±10%
50-60
Hz
500
mA
Max.
Unit marked for 220V~ operation
220V~ ±10%
50-60
Hz
250
mA
Max.
Installation Class III
Replacement Fuses
Replace fuses with main power OFF! (o)
Replace fuses with "TT" time delay fuses of specified rating only!
TLG-4500 models marked for 120V~ operation require a .5A 20mm x 5mm type TT fuse.
TLG-4500 models marked for 220V~ operation require a .25A 20mm x 5mm type TT fuse.