MiniVent M1/
100/120
N / C
Installation and Operation Instructions
3
UK
CHAPTER 2
GENERAL OPERATING
INSTRUCTIONS
1.9
Performance data
The unit type plate gives an indication of the mandatory electrical values; which must be coordinated with the local
supply network. The fan performances* were established on a test stand according to DIN EN ISO 5801.
1.10 Noise data
Noise data that refers to certain distances apply to free field conditions. With regard to installation, the sound pressu-
re level can differ significantly from the catalogue data, as it is highly dependent on the installation conditions, i.e. on
the absorption capability of the room and the room size among other factors.
2.0
Personnel qualification
The electrical connection and start-up as well as installation, servicing and maintenance of the fan
must only be carried out by qualified electricians.
– MiniVent
M1
/100/120
N / C
mini fans can be used by children over the age of 8 as well as persons with physical,
sensory, or mental disabilities or lack of experience and knowledge, if they are supervised or instructed with regard to
the safe use of the unit and they understand the resulting risks. Children must not play with the unit. Cleaning or user
maintenance must not be carried out by unsupervised children.
2.1
Protection against contact
MiniVent
M1
/100/120
N / C
mini fans do not require a protection guard, as they meet the requirements of DIN EN
60335-2-80 section 20.101.
2.2
Motor protection device
The motors of the MiniVent
M1
/100/120
N / C
are equipped with thermo contacts, which are wired in series with the
winding, and which automatically switch off and on again after cooling.
3.0
Type overview MiniVent M1/1.. N / C
M1
/100
N / C
with codable overrun timer and interval operation
Ref.No. 6172.003
M1
/120
N / C
with codable overrun timer and interval operation
Ref.No. 6361.003
3.1
Technical data
M1/100 N / C
Impeller Ø [mm]
92
Electrical supply line
NYM-O 3 x 1.5 mm²
Alternating current
1~
Protection category
IP 45 (water jet protection)
Voltage/frequency
230 V, 50 Hz
Protection class
II
Power consumption [W]
9/5
Weight approx. [kg]
0.8
Rated current [mA]
0.06/0.04
Speed [1/min]
2650/2250
Flow volume [m
3
/h]
90/75
M1/120 N / C
Impeller Ø [mm]
111
Electrical supply line
NYM-O 3 x 1.5 mm²
Alternating current
1~
Protection category
IP 45 (water jet protection)
Voltage/frequency
230 V, 50 Hz
Protection class
II
Power consumption [W]
13/10
Weight approx. [kg]
1.05
Rated current [mA]
0.09/0.08
Speed [1/min]
2350/2050
Flow volume [m
3
/h]
170/150
CHAPTER 3
TECHNICAL DATA /
DIMENSIONS
Summary of Contents for M1/100 N/C
Page 18: ...MiniVent M1 100 120 N C Montage und Betriebsvorschrift 16 Notizen D...
Page 19: ...MiniVent M1 100 120 N C Montage und Betriebsvorschrift 17 D Notizen...
Page 38: ...MiniVent M1 100 120 N C Installation and Operation Instructions 16 Notes UK...
Page 39: ...MiniVent M1 100 120 N C Installation and Operation Instructions 17 UK Notes...