49
E
9.3 Signalling at night (between 10 pm and 6 am CET*)
Audible alarm LED
Cause
What needs to be done?
Off
Flashes every
48 seconds
dimmed
Normal
operation
----
Once every
48 seconds
Flashes every
8 seconds
Failure
Replace smoke detector with new
one. Acknowledge by pressing
the test button.
* Central European winter time
9.4 Signalling after acknowledgement
Audible alarm LED
Cause
What needs to be done?
Switched off for
24 hours after
pressing the test
button
Flashes every
48 seconds
Battery low
Smoke detector is still ready for
operation, but should be replaced
with a new one after a period of
30 days at the latest (change of
battery not possible).
Switched off for
24 hours after
pressing the test
button
Switched off
for 24 hours
after pressing
the test
button
Failure (low
battery is not
indicated at
night)
Smoke detector is not ready for
operation any more and has to
be replaced by a new one.
If a detector is completely turned off after acknowledgement of a failure (removed from the base for more
than 5 minutes), the detector indicates the failure again after repeated start-up.
7002739__MA Genius Hx_de-en-fr_110530.indb 49
06.06.2011 10:29:20
Summary of Contents for Genius H
Page 2: ...2 7002739__MA Genius Hx_de en fr_110530 indb 2 06 06 2011 10 29 13...
Page 4: ...4 7002739__MA Genius Hx_de en fr_110530 indb 4 06 06 2011 10 29 13...
Page 30: ...30 7002739__MA Genius Hx_de en fr_110530 indb 30 06 06 2011 10 29 17...
Page 32: ...32 7002739__MA Genius Hx_de en fr_110530 indb 32 06 06 2011 10 29 17...
Page 58: ...58 E 7002739__MA Genius Hx_de en fr_110530 indb 58 06 06 2011 10 29 21...
Page 60: ...60 7002739__MA Genius Hx_de en fr_110530 indb 60 06 06 2011 10 29 21...
Page 85: ...85 7002739__MA Genius Hx_de en fr_110530 indb 85 06 06 2011 10 29 25...