2 of 2 | 13.12.2018
Connect the corresponding power lines with the cable connector. Connect the green-yellow protective
conductor first and then the other two cables. The brown (or black) cable is generally the phase
conductor - connect this to the terminal marked with "L". The blue conductor must be connected to the
terminal marked with "N".
Do not bend the cables; make sure that the cables and plugs are not subject to tension or torsional
forces. Protect all cables and insulation against possible damages.
Check proper connection once again.
Switch the building installation's fuse switch back on.
5. Faulty Function
Are power lines properly connected?
Is the circuit breaker switched back on?
6. Technical Data
7. Care
Disconnect the entire product from the mains first and let it cool down before cleaning or maintaining the
product.
8. Waste Disposal
The product can be disposed of in the household waste.
Article
Port
Protection type
45608
Max. 230 V, 16 A; 3-pole 1.0 - 1.5
mm²
IP 68, 1m max.
1/2h
45609 T-connector
Max. 230 V, 16 A; 3-pole 1.0 - 1.5
mm²
IP 68, 1m max.
1/2h
45611
Max. 230 V, 16 A; 5-pole 1.0 - 1.5
mm²
IP 68, 1m max.
1/2h