7. Operation Instruction
6 . Anti-Legionella Function
If user uses sanitary hot water directly out from the HWT (hot water tank), for the health purpose
,
it’s requested that he needs to heat up the water inside the tank over 60
℃
for anti-legionella purpose
once a week
.
Note:Please always refers to local regulation for a correct usage of this function.
6.01 Anti-Legionella Program
Turn ON/OFF Anti-Legionella function.
6.02 Day and Time
Set at which time in which weekday(s) for the start of anti-legionella operation
.
6.03
Setpoint
Set the target sanitary hot water temperature for anti-legionella. Please refers to the local
regulation for the correct setting of this temperature.
6.04
Duration
Set for how long the unit should try to keep this set high temperature, to ensure all bacteria
in the shower water tank can be killed
.
6.05 Finish Time
Set an ending time for this anti-egionella function, even it is not finished successfully
.
This time should be longer than what it is set in parameter 6.04.