background image

Operation

1.After unit starts, select your desired operation mode.

2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:

BLANK

TIMER ON

TIMER OFF

TIMER ON-OFF

Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). "        "or "       "will flash.

3.Press        /

button to set time.

It can be adjusted within 24 hours.

Hints:
After replacing batteries or a power failure happens, time
setting should be reset.

According to the Time setting sequence of TIMER ON or

TIMER OFF, either Start-Stop or Stop-Start can be achieved. 

 Timer On/Off  On-Off Operation 

CE

All the products are in conformity with the following 
European provision:
- Low Voltage Directive 2014/35/EU
-Electomagnetic CompatibilitY 2014/30/EU 

ROHS

The products are fulfilled with the requirements in the 
directive

2011/65/EU

 of the European p arliament and of

council on the Restriction of the use of Certain Hazardous
Substances in Electrical and Electronic Equipment (EU 
RoHS Directive)

WEEE

DISPOSAL REQUIREMENTS:

Your air conditioning product is marked with this
symbol.This means that electrical and electronic
products shall not be mixed with unsorted 
household waste. Do not try to dismantle the 
system yourself : the dismantling of the air

EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS

1

1+2=

kg

R32

2

kg

2=

1=

B

C

D

F

E

kg

A

This product contains fluorinated greenhouse gases covered by 
the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R32
GWP* value:675
GWP=global warming potential
Please fill in with indelible ink,

 and

on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop value cover).
A  contains fluorinated greenhouse gases covered by the Kyoto 
Protocol
B  factory refrigerant charge of the product: see unit name plate
C   additional refrigerant amount charged in the field
D   total refrigerant charge
E   outdoor unit
F   refrigerant cylinder and manifold for charging 

IMPORTANT INFORMATION REGA-
RDING THE REFRIGERANT USED

In accordance with the directive 

2012/19/EU

of the European

parliament, herewith we inform the consumer about the dis-
posal requirements of the electrical and electronic products.

conditioning system,treatment of the refrigerant, of oil and of
other part must be done by a qualified installer in 

accordance

with relevant local and national legislation. Air conditioners 
must be treated at a specialized treatment facility for reuse, 
recycling and recovery. By ensuring this product is disposed 
of correctly, you will help to prevent potential negative cons-
equences for the environment and humen health. Please 
contact the installer or local authority for more information. 
Battery must be removed from the remote controller and dis-
posed of separately in accordance with relevant local and 
nationl legislation.

Contains fluorinated greenhouse gases
covered by the Kyoto Protocol

 Healthy airflow Operation

1.Press          to starting

Setting the comfort work conditions.

2.The setting of healthy airflow function

Note:

1.After setting the healthy airflow function, the position 

 grill is fixed.

4.In cooling and dry, using the air conditioner for a long 

time under the high air humidity, condensate water may
occur at the grille .

3.The cancel of the healthy airflow function

Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote 
controller.

2.In heating, it is better to select the
3.In cooling, it is better to select the 

mode.

mode.

TIMER OFF-ON

0.5h

0.5h

0.5h

0.5h

Press the button for each time, setting time in the first 
12 hours increased by 0.5 hour every time, after 12 
hours,increased by 1 hour every time.
Press the button for each time, settiing time in the first 
12 hours decreased by 0.5 hour every time, after 12 
hours,decreased by 1 hour every time.

After adjust the time,press          button and confirm the
time ON or OFF button will not flash any more.

4.Confirm timer setting

5.Cancel timer setting
Press the timer button by times until the  time display 
eliminated.

Press           button to enter additional options,Press this 
button continuously, the louvers location will cycle between 
in the following three locations, to choose the swing location 
what you needed,and then press          button to confirm.

Press          button to enter additional options,Press this 
button continuously, the louvers location will cycle between 
in the following three locations again,and then press
button to cancel.

Healthy
airflow
upwarder

Healthy
airflow
downwarder

Present
position

Voltage:230V

Climate:T1

4

Summary of Contents for JS026-B1

Page 1: ...ion manual before using the air conditioner Keep this operation manual for future reference This appliance is filled with R32 SPLIT TYPE ROOM AIR CONDITION OPERATION MANUAL 0010598298 ER JS026 B1 JS03...

Page 2: ...ontacts should not be no less than 3mm Such means for disconnection must be incorporated in the Make sure installation is done according to local wiring regulation by professional persons A leakage ex...

Page 3: ...9 1 2 8 5 Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLAION MAINTENANCE CAUTIONS TROUBLE SHOOTING 10...

Page 4: ...y 6 TIMER OFF display TIMER ON display 7 TEMP display 16 LOCK button Used to lock buttons and LCD display 25 RESET button When the remote controller appears abnormal use a sharp pointed article to pre...

Page 5: ...de but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode sleep operation is not available Emergency Operation Use this operation only when the remote controll...

Page 6: ...after SLEEP mode starts temp will become 2 lower than temp setting After another 1 hours temp decrease by 2 rises by 1 futher The unit will run for further 3 hours then stops Temp is lower than temp...

Page 7: ...electrical and electronic products conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and national legisl...

Page 8: ...disturbed Place possible to drain easily where piping can be conne cted with the outdoor unit Place where cold air can be spread in a room entirely Place nearby a power receptacle with enough space ar...

Page 9: ...the drain hose then fasten them with the adhesive tape Left Left rear piping In case of left side piping cut away with a nipper the lid for left piping In case of left rear piping bend the pipes accor...

Page 10: ...to wiring error Faulty PCB Faulty EEPROM data Faulty EEPROM Faulty PCB Faulty connector connection Faulty therm istor Faulty PCB Room temperature sensor failure The power source must be exclusively us...

Page 11: ...door unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter T...

Page 12: ...TION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or re...

Page 13: ...is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V The refrigerating circuit is leak proof 1 Applicable ambient temperature range Specifications The machine is a...

Page 14: ...1 2 8 5 10 6SLV WUH FL I I FUNKCJE 2 6 8GA M217 JEDNOSTK 1 TRZNEJ KONSERWACJA 52 26752 12 CI R2 1 PROBLEM W tej instrukcji 32 producenta powierzchni co najmniej 1 2m2 8 lokalnymi normami 07RN F 3 R32...

Page 15: ...ego modelu kratka wlotu mo e si r ni si w rzeczywisto ci od tej pokazanej w instrukcji obs ugi 2 3 1 2 3 1 Wy wietlacz Wska nik trybu pracy zapala si gdy spr arka pracuje Wy wietlacz temperatury pomie...

Page 16: ...RZDQLD 2 0 872 LVSOD FLUFXODWHG 3UDFD DZDU MQD L NRQWUROQD 5HJXODFMD NLHUXQNX QDZLHZX SRZLHWU D 3UDFD DZDU MQD 2SFM SUDF DZDU MQHM QDOH Z NRU VW ZD MHG QLH ZWHG JG SLORW GDOQHJR VWHURZDQLD RVWDQLH XV...

Page 17: ...OL V PERO EXG LND ODZLV 21 50 1 Z ZR D ZWHG IXQNFM SUDF QRFQHM 8ZDJD D F HQLH IXQNFML 785 2 Z WU ELH FK RG HQLD 22 VSRZRGXMH QLHUyZQRPLHUQ UR N DG WHPSHUDWXU Z SRPLHV F HQLX 8WU P ZDQLH SU H G X V F D...

Page 18: ...U E SUDF L WHPSHUDWXU QLFMRZDQLH IXQNFML GURZRWQHJR QDGPXFKX SRZLHWU D FLVNDM F NODZLV 75 81 7 21 QDOH SU HM GR IXQNFML GRGDWNRZ FK L Z EUD MHGQ GZyFK RSFML QDGPXFKX SRZLHWU D QD ZSURVW XSZDUGHU Z Gy...

Page 19: ...iedni przestrzeni wok Miejsce w odleg o ci 1m od odbiornik w telewizyjnych radiowych urz dze bezprzewodowych i wietl wek W sytuacji zamontowania pilota do ciany miejsce gdzie jednostka wewn trzna b dz...

Page 20: ...ie ci w szczelinie materia u izolacyjnego jednostki wewn trznej 2 Umie ci wewn trzno zewn trzny kabel elektryczny z tylnej strony jednostki wewn trznej i wyci gn go z przodu a nast pnie pod czy 3 Prz...

Page 21: ...5 2 0mm Prawid owy Nieprawid owy Nachylony Uszkodzony ko nierz P kni cie Cz ciowy Zbyt rozchylony na zewn trz 7 Odp yw W odprowadzaj cy skropliny powinien tworzy lekk pochy o ku do owi Nie nale y wyk...

Page 22: ...h rodk w czyszcz cych 4 Zamontowa filtr standardowy konieczne UWAGA Bia a strona filtra fotokatalicznego powinna by zwr cona na zewn trz a czarna ku urz dzeniu Z kolei zielona strona filtra antybakter...

Page 23: ...j cego ZABRONIONE Wk adanie przedmiot w do otworu wylotowego i wlotowego zabronione Zabrania si pod czania i od czania urz dzenia od pr dy przez ci gniecie kabla Zabrania si kierowania strumienia powi...

Page 24: ...iep a rodki ostro no ci Zastawienia lub przykrywanie kratek klimatyzatora zabronione Wk adanie palc w i innych przedmiot w do wlotu i wylotu oraz pomi dzy prowadnice zabronione Obs uga urz dzenia prze...

Reviews: