Operation

   Air Flow Direction Adjustment

Press FAN button. For each press, fan speed 

follows:

Remote controller:

Press

button

Every time the button is pressed, temp.setting
increase 1

o

C,if kept depressed, it will increase

rapidly

Every time the button is pressed, temp.setting

decrease 1

o

C,if kept depressed, it will 

decrease  rapidly

Select a desired temperature.

4.Fan speed selection

3.Select temp.setting

Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.

1. Unit start

 Press ON/OFF on the remote controller, unit starts.

Base  Operation

Remote controller

When restart after remote turning off, the remote controller 

Move the vertical blade by a knob on airconditioner

to adjust left and right direction referring to Fig.

4.Left and right air flow adjustment(manual)

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur 

It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY

otherwise, condensate water might occur.

Emergency operation and test operation

adjusted to left or at air outlet if all vertical louvers are right. 

mode ,

controller will automatically memorize the previous set swing position.

Note:

changes as

Operation

Mode

Remote

Controller

Note

In DRY mode , when room temperature becomes lower
than temp.2

o

C, unit will run intermittently at LOW 

speed regardless of FAN setting. 

Under the mode of auto operation, air conditioner will

automatically select Cool or Heat operation according to

room temperature. When FAN is set to AUTO the air 

conditioner automatically adjusts the fan speed according
to room temperature.

In FAN operation mode , the unit will not operate in COOL or
HEAT mode  but only in  FAN mode, AUTO is not available in

FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.

Emergency Operation:

Use this operation only when the remote controller is defective 
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation. 
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in 
the following modes:

    Room
temperature

Designated
temperature

Timer
mode

Fan

speed

Operation

mode

  Above 23

o

C

  Below 23

o

C

 

23

o

C

 26

o

C

No

AUTO

AUTO

COOL

HEAT

No

It is impossible to change the settings of temp. and fan speed,It 
is also not possible to operate in timer or dry mode.

temperature is below 16

o

C, do not use it in the 

Test operation:

Use this switch in the test operation when the room

normal operation.

 your finger from the switch: the cooling

Continue to press the test operation 

switch for more than 5 seconds . After

 you hear the "Pi" sound twice, release

Test ope ration switch is the same as emergency switch.

operation starts with the air flow speed "Hi".

Under this operation mode,the fan motor of indoor

unit will run in high speed.

LOW

MED

HI

AUTO

2. Select operation mode

COOL button:Cooling mode
HEAT button: Heating mode
DRY button: Dehumidify mode

Display

circulated

Pi

Pi Pi

DRY

COOL

AUTO

HEAT

FAN

In HEAT mode, warm air will blow out after

a

short

period of the time due to cold - draft prevention function.
When FAN is set to AUTO, the air conditioner automatically
adjusts the fan speed according to room temperature.

4

Remote controller

Press           button again ,vertical flap will stop over 

present position,

the swing function will be cancelled

2.Press          button.  changes as follows:

COOL/DRY/AUTO(Initial state):

HEAT(Initial state):

1.Vertical flap

Pos.1

Pos.2

Pos.3

3.Press

button  to choose the  Pos.2 and Pos.3.

Pos.4

Pos.5

Pos.4

(Autoswing)

(no)

2

Summary of Contents for JS026-B1

Page 1: ...ion manual before using the air conditioner Keep this operation manual for future reference This appliance is filled with R32 SPLIT TYPE ROOM AIR CONDITION OPERATION MANUAL 0010598298 ER JS026 B1 JS03...

Page 2: ...ontacts should not be no less than 3mm Such means for disconnection must be incorporated in the Make sure installation is done according to local wiring regulation by professional persons A leakage ex...

Page 3: ...9 1 2 8 5 Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLAION MAINTENANCE CAUTIONS TROUBLE SHOOTING 10...

Page 4: ...y 6 TIMER OFF display TIMER ON display 7 TEMP display 16 LOCK button Used to lock buttons and LCD display 25 RESET button When the remote controller appears abnormal use a sharp pointed article to pre...

Page 5: ...de but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode sleep operation is not available Emergency Operation Use this operation only when the remote controll...

Page 6: ...after SLEEP mode starts temp will become 2 lower than temp setting After another 1 hours temp decrease by 2 rises by 1 futher The unit will run for further 3 hours then stops Temp is lower than temp...

Page 7: ...electrical and electronic products conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and national legisl...

Page 8: ...disturbed Place possible to drain easily where piping can be conne cted with the outdoor unit Place where cold air can be spread in a room entirely Place nearby a power receptacle with enough space ar...

Page 9: ...the drain hose then fasten them with the adhesive tape Left Left rear piping In case of left side piping cut away with a nipper the lid for left piping In case of left rear piping bend the pipes accor...

Page 10: ...to wiring error Faulty PCB Faulty EEPROM data Faulty EEPROM Faulty PCB Faulty connector connection Faulty therm istor Faulty PCB Room temperature sensor failure The power source must be exclusively us...

Page 11: ...door unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter T...

Page 12: ...TION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or re...

Page 13: ...is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V The refrigerating circuit is leak proof 1 Applicable ambient temperature range Specifications The machine is a...

Page 14: ...1 2 8 5 10 6SLV WUH FL I I FUNKCJE 2 6 8GA M217 JEDNOSTK 1 TRZNEJ KONSERWACJA 52 26752 12 CI R2 1 PROBLEM W tej instrukcji 32 producenta powierzchni co najmniej 1 2m2 8 lokalnymi normami 07RN F 3 R32...

Page 15: ...ego modelu kratka wlotu mo e si r ni si w rzeczywisto ci od tej pokazanej w instrukcji obs ugi 2 3 1 2 3 1 Wy wietlacz Wska nik trybu pracy zapala si gdy spr arka pracuje Wy wietlacz temperatury pomie...

Page 16: ...RZDQLD 2 0 872 LVSOD FLUFXODWHG 3UDFD DZDU MQD L NRQWUROQD 5HJXODFMD NLHUXQNX QDZLHZX SRZLHWU D 3UDFD DZDU MQD 2SFM SUDF DZDU MQHM QDOH Z NRU VW ZD MHG QLH ZWHG JG SLORW GDOQHJR VWHURZDQLD RVWDQLH XV...

Page 17: ...OL V PERO EXG LND ODZLV 21 50 1 Z ZR D ZWHG IXQNFM SUDF QRFQHM 8ZDJD D F HQLH IXQNFML 785 2 Z WU ELH FK RG HQLD 22 VSRZRGXMH QLHUyZQRPLHUQ UR N DG WHPSHUDWXU Z SRPLHV F HQLX 8WU P ZDQLH SU H G X V F D...

Page 18: ...U E SUDF L WHPSHUDWXU QLFMRZDQLH IXQNFML GURZRWQHJR QDGPXFKX SRZLHWU D FLVNDM F NODZLV 75 81 7 21 QDOH SU HM GR IXQNFML GRGDWNRZ FK L Z EUD MHGQ GZyFK RSFML QDGPXFKX SRZLHWU D QD ZSURVW XSZDUGHU Z Gy...

Page 19: ...iedni przestrzeni wok Miejsce w odleg o ci 1m od odbiornik w telewizyjnych radiowych urz dze bezprzewodowych i wietl wek W sytuacji zamontowania pilota do ciany miejsce gdzie jednostka wewn trzna b dz...

Page 20: ...ie ci w szczelinie materia u izolacyjnego jednostki wewn trznej 2 Umie ci wewn trzno zewn trzny kabel elektryczny z tylnej strony jednostki wewn trznej i wyci gn go z przodu a nast pnie pod czy 3 Prz...

Page 21: ...5 2 0mm Prawid owy Nieprawid owy Nachylony Uszkodzony ko nierz P kni cie Cz ciowy Zbyt rozchylony na zewn trz 7 Odp yw W odprowadzaj cy skropliny powinien tworzy lekk pochy o ku do owi Nie nale y wyk...

Page 22: ...h rodk w czyszcz cych 4 Zamontowa filtr standardowy konieczne UWAGA Bia a strona filtra fotokatalicznego powinna by zwr cona na zewn trz a czarna ku urz dzeniu Z kolei zielona strona filtra antybakter...

Page 23: ...j cego ZABRONIONE Wk adanie przedmiot w do otworu wylotowego i wlotowego zabronione Zabrania si pod czania i od czania urz dzenia od pr dy przez ci gniecie kabla Zabrania si kierowania strumienia powi...

Page 24: ...iep a rodki ostro no ci Zastawienia lub przykrywanie kratek klimatyzatora zabronione Wk adanie palc w i innych przedmiot w do wlotu i wylotu oraz pomi dzy prowadnice zabronione Obs uga urz dzenia prze...

Reviews: