6
196349 rev 1
EN
Tips:
When starting in the lowest position, the lift can
jump a small distance; fine tuning of height is done
instead by lowering the lift to the right position
6.1 Start up
Carry out the following functional checks before use:
•
Ensure that no persons or objects are in the working
area of the dryer.
•
Ensure that the compressed air supply and electric-
ity is available.
•
Shift the switch lever on the pneumatic control panel
to the lift-UP position until the IR platform reaches
the upper stop position.
•
Shift the switch lever on the pneumatic control panel
to the lower-DOWN position until the IR platform
reaches the lower stop position.
•
Repeat the lifting and lowering movements several
times.
Also, see Chapter 1 Safety Instructions.
6.2 Compressed air connection
Use a coupling connector to connect up to the line’s
quick-release coupling (R ½“ on-site supply). The cou-
pling must lock into place!
Use dehumidified, non-lubricated compressed air only.
Connect the air supply line before starting work and
disconnect again after leaving the working platform.
A filter regulator must be installed in the air supply li ne
(air filter and water separator).
6.3 Operation of the IR lamps
Control panel
1.
The lights turn green when the correct distance
obtained between IR lamps and object. This distance
must be checked before the IR lights turned on. During
operation with IR lamps, these lights may blink because
of distance sensors are disturbed by the infrared light.
Note the lights are only an aid to find the right position
towards the object it is possible to start the IR lamps
although the lights are not green.
2.
Start of the fully automatic IR program. Infrared
lamps turn off automatically after the drying period ends.
3.
Infrared lamps, manual stop of process.
4.
Indicator light that indicates that a process failure
occurred. The alarm only stops the actual zone that has
the failure. See also Appendix 1.
5.
Emergency stop IR lamps.
6.
For daily use are not needed three touch control
panels used. See Chapter 6.4 to 9 for the setting of the
control system and temperatures.
Distance sensor and zone location
6.4 Keyboard
Software defined button
Confirmation choices
Software defined button
Cancellation choices
Start/
Stop
1-3 outputs
Temperature control
On/Off (Optional)
Enter
6.5 Display
Flash off – active
Full bake – inactive
Temperature control
activated
Confirmation choices
Edit temperature
Active program without pyrometer
Flash off – active
Full bake – inactive
Temperature control
activated
Confirmation choices
Edit temperature
Active program with pyrometer