background image

5

196349 rev 1

EN

4. Instructions to the owner

The owner of the dryer must produce clear operating 
instructions, adapted to local site conditions, and make 
these available to all users who have to observe these 
operating instructions.
This dryer is not intended for use by persons (including 
children) with reduced physical, sensory or mental capa-
bilities, or lack of experience and knowledge, unless they 
have been given supervision or instruction concerning 
use of the dryer by a person responsible for their safety.
No additional equipment is to be attached to the dryer.
Dispose of used items at the nearest environmental pro-
tection facility for recycling.
For safety reasons the infrared dryer must be supplied by 
recommended maximum fuse, see table in chapter 3.2.

5. Assembly instruction

The IRT Siemens Leading Edge Protection Dryer is de-
livered fully assembled and need only air and electricity 
to work but when installing the dryer it is imperative that 
the following safety instructions are always observed – it 
helps prevent life-threatening injuries, damage to the 
machine and other property.
Only qualified persons heeding the safety instructions 
are permitted to carry out the installation work.

The dryer must be examined for any possible trans-
port damage before starting the installation work.

Ensure that only authorized persons are in the work-
ing area and that no other persons are at risk due to
the installation works.

All machine connections (hoses) must be laid so that
there is no risk of tripping over them.

Also read the General Safety Instructions chapter.

Unauthorized tampering invalidates the guarantee.

5.1  Environmental installation conditions

Siemens Leading Edge Protection Dryer is only suitable 
for use in enclosed, dry and covered premises.
Ensure that there is sufficient space away from objects, 
walls and ceilings before installation.
It is important to ensure that the minimum distances (ac-
cording to the relevant national regulations and work-
place regulations) to the hall walls or other equipment, 
escape routes, etc. are kept to ensure safe working.
The floor should be flat with a maximum gradient of 
2.5% (1/40, i.e., 2.5 cm per 100 cm) and the load capac-
ity of the floor must be able to bear the permissible total 
weight of the dryer. The operator of the dryer is respon-
sible for selecting a suitable installation site.
The dryer is only to be used at sites with temperatures 
ranging from 10°C to 50°C. 
An adequately sized compressed air connection (hose 
1/2 “, Pmax = 8 bar) must be provided.
Use dehumidified, non-lubricated compressed air only. 
A filter regulator must only be installed in the air supply 
line (air filter and water separator).

6. Basic instruction for operation

Move the dryer to the site where you want to use it. This 
can only be done from the shorter side of the undercar-
riage with help of a fork lift or by pushing or pulling in 
the four handlebars one at each corner of the mobile 
dryer. For manual movement it is recommended to be at 
least two persons to maintain safe and ergonomic work.

The dryer is only to be moved when it is in the start posi-

tion (completely lowered) and without anybody or any 

load on it. 

Small adjustments length and sideways can be made 
in elevated positions to get the green lights from the 
distance indicators. All movements of the IRT Siemens 
Leading Edge Protection Dryer are to be made with help 
of the four handle bars one at each corner at the base. 
No adjustments or movement of the dryer are to be 
made by applying force to the scissor/lifting part of the 
mobile dryer or frame with the IR heaters mounted on 
the lifting platform. 
Stop the undercarriage from moving by locking the 
brakes on the four rollers. Check that the brakes are 
working!
Watch your step carefully and keep a safe distance from 
other objects, escape routes, walls and ceilings.
The maximum permissible gradient is 2.5% (1/40, cor-
responding to 2.5 cm per 100 cm).
Use a coupling connector to connect to the line’s quick-
release coupling (Pmax = 8 bar/on-site supply). The 
coupling must lock into place!
The dryer has an 

EMERGENCY-RELEASE switch

. The 

platform can be lowered by a person standing next 
to the platform in the case of a control valve failure. In 
this case, the emergency release switch must be held 
pressed down until the start position is reached.

Proceed as follows to lift the IR platform:

Open the shut-off valve on the hand lever valve. Press 
the hand lever valve upwards and hold it until there until 
the required lifting height or the end position is reached. 
Take note of the hazardous areas whenever possible.
Releasing the hand lever valve automatically returns the 
valve back to the 0 position and the lifting process is ter-
minated immediately. The lifting process stops automati-
cally when the maximum lifting height is reached.

Proceed as follows to lower the IR platform:

Check the hazardous area to make sure no persons or 
objects are in the dryer´s working area.
Press the hand lever valve downward and hold it there 
until the start position is reached or the lowering process 
is automatically terminated. Take note of the hazardous 
areas whenever possible.
Releasing the hand lever valve automatically returns the 
valve back to the 0 position and the lowering process is 
terminated immediately.
Close the shut-off valve on the hand lever valve before 
leaving.

Summary of Contents for IRT System Series

Page 1: ...196349 rev 1 Hedson Technologies AB 2018 IRT Dryer Siemens Leading Edge Protection EN Operation Manual original language...

Page 2: ...wner 5 5 Assembly instruction 5 6 Basic instruction for operation 5 7 Program mode 8 8 Extended usage information 9 9 Settings mode 9 10 Maintenance and Service 12 11 Spare parts 14 12 Safety inspecti...

Page 3: ...ounted on the lifting platform 1 Safety instructions 1 1 Operator s duty of care The IRT Siemens Leading Edge Protection Dryer is designed and built after a hazard assessment was con sidered and follo...

Page 4: ...king under the raised working platform and during its lifting and lowering movements is not permitted 3 Product description The IRT Siemens Leading Edge Protection Dryer is a maneuverable infrared dry...

Page 5: ...ir only A filter regulator must only be installed in the air supply line air filter and water separator 6 Basic instruction for operation Move the dryer to the site where you want to use it This can o...

Page 6: ...amps Control panel 1 The lights turn green when the correct distance obtained between IR lamps and object This distance must be checked before the IR lights turned on During operation with IR lamps th...

Page 7: ...ered This is normally not a part of the everyday usage To enter the settings mode press both arrow keys when you turn the main switch to position 1 Read chapter 9 for more information 6 8 Program inte...

Page 8: ...is finished If this happens check the cooling system of the con trol unit fan filter or ambient temperature 3 Paint Temperature Alarm Also called Process alarm see 8 2 Option if pyrometer is used 4 Fi...

Page 9: ...ram is terminated In case of process alarm check if the temperature measuring device pyrometer is aligned correctly on the surface to be dried and that it is not registering unwanted material temperat...

Page 10: ...o select no yes Press select to confirm 9 4 6 7 Basic PIN Code You can change the PIN code to prevent unauthor ized access to the basic setting as described in table in chapter 9 4 To do this use the...

Page 11: ...t 4 Cassette IR Test The IR cassette lamps output I light up Check that all the IR lamps are lit For safety reasons this test is limited to 10 seconds Press enter or next to continue Test 5 Ventilator...

Page 12: ...uitably trained personnel Do not use running water or flammable liquids for clean ing Abide by the following points to ensure a long service life and continuous operation of the dryer Only original sp...

Page 13: ...round the lamp until the fit ting is completed 1 Loosen the mounting screws on both end cov ers 2 Loosen both lamp end protections 3 Pull the protection out of the slide The screws for the lamp holder...

Page 14: ...st environmental pro tection facility for recycling 11 Spare parts The following spare parts are the most common ones for the SingleHeater IR units Part Part nr 1 Fan 202024 2 Filter 103055 3 IR lamp...

Page 15: ...s to the zero position when released Fall arrester function Emergency release status Air bellows status Supporting structure status Function test Lifting lowering Function test Lifting lowering with l...

Page 16: ...lowing standard s or other normative document s EN 61000 6 4 Electromagnetic Compatibility Generic Emission Standard EN 61000 6 3 Electromagnetic Compatibility Generic Immunity Standard EN 60204 1 Saf...

Page 17: ...appendix 1 761 054_PNTS 77 Electrical diagram for IRT Siemens Leading Edge Protection Dryer equipment is found in the appendix 2 15 Weights and Dimensions The overall weight is 665 kg Dimensions as b...

Page 18: ...sette tripped Check fans filters hoses and ambient tempera ture Reset by pressing the temp switch button Lifting malfunction Maintenance unit manometer without mains pressure Ensure the mains pressure...

Page 19: ...70 196349 rev 1...

Page 20: ...53 42 00 Telefax 46 0 40 43 29 01 www hedson com HEDSON TECHNOLOGIES AB Box 1530 SE 462 28 V nersborg Tel 46 0 40 53 42 00 Telefax 46 0 521 669 09 www hedson com Hedson Technologies 2017 The manufact...

Reviews: