14
196349 rev 1
EN
10.4 Air bellows
The air bellow is a flexible element specially designed for
use in the lifting platform. The rubber cover is subject to
aging processes and must be checked carefully. Record-
ed data shows that a well-kept air bellows has a service
life of over 20 years.
Tips for a long service life:
•
Use dry and oil-free compressed air.
•
Protect from UV radiation (e.g. from welding or UV
dryers).
•
Avoid the use of chemical products.
•
Protect from mechanical damage (dents, etc.).
•
Abide by the maintenance and care instructions, see
10.1.
Damaged air bellows must be replaced. Only original
parts from the manufacturer can be used
10.5 Comments on the filter regulator and air
supply lines
The filter regulator is not included in the Siemens Lead-
ing Edge Dryer package. A filter regulator must be in-
stalled in the air supply line (provided by the customer).
Use dehumidified, non-lubricated compressed air only.
Follow the instructions and recommendations provided
by the manufacturer of the filter regulator during mainte-
nance and cleaning.
10.6 Comments on the scissors' sliding areas
Due to the design principles, very strong forces are pres-
ent on the sliding surfaces of the scissors. These forces
can lead to grooving in the sliding surfaces. They will not
affect the operation of the dryer.
The maintenance intervals described in 10.1 and other
manuals must be adhered to.
10.7 Disposal
Dispose of used items at the nearest environmental pro-
tection facility for recycling.
11. Spare parts
The following spare parts are the most common ones for
the SingleHeater IR-units.
Part
Part nr.
1 Fan
202024
2 Filter
103055
3
IR lamp 790 mm 3 kW
102701
4
Lamp holder
109790
5
Temp switch
126043
Distance sensor
195266
Pyrometer
750231
6
Reflector E790 Gold foil
102696
6
Reflector E790 Net
193646
6
Reflector E790 Glass
716238
Printed Circuit Board (PCB)
750321
Solid State Relay (SSR)
750227
Display
750220
Spare parts for Herkules working platform, see appendix
1: 761-054_PNTS-77
For other spare parts, please contact:
Hedson Technologies AB
Box 1530
462 28 Vänersborg
Sweden
Tel.
+46 (0)521 28 12 30
Fax
+46 (0)521 28 12 31
E-mail: [email protected]
12. Safety Inspections
The safety inspection is required to ensure operational
safety of the dryer.
The following must be performed:
•
Before commissioning the dryer at the manufac-
turer’s, use the Regular Safety Inspection form, see
12.1.
•
After the initial commissioning, check at regular
intervals as per chapter 10. Use the Regular Safety
Inspection form, see 12.1.
•
Enter the condition of the lifting platform in a sepa-
rate copy of the inspection log and attach it to the
operating manual.
Note!
The regular safety checks must be performed by a
suitably trained person. It is advisable to also implement
maintenance at the same time.
Note!
After a replacement part has been attached during
service to the lifting equipment always perform a Regular
safety inspection
Contact Hedson Technologie's customer service depart-
ment if you have any further questions.
E-mail [email protected]
5
6
3
Glass
3
6
4
4
2
1
Net
Summary of Contents for IRT System Series