background image

14

196349 rev 1

EN

10.4  Air bellows

The air bellow is a flexible element specially designed for 
use in the lifting platform. The rubber cover is subject to 
aging processes and must be checked carefully. Record-
ed data shows that a well-kept air bellows has a service 
life of over 20 years.
Tips for a long service life:

Use dry and oil-free compressed air.

Protect from UV radiation (e.g. from welding or UV
dryers).

Avoid the use of chemical products.

Protect from mechanical damage (dents, etc.).

Abide by the maintenance and care instructions, see
10.1.

Damaged air bellows must be replaced. Only original 
parts from the manufacturer can be used

10.5  Comments on the filter regulator and air 

supply lines

The filter regulator is not included in the Siemens Lead-
ing Edge Dryer package. A filter regulator must be in-
stalled in the air supply line (provided by the customer). 
Use dehumidified, non-lubricated compressed air only. 
Follow the instructions and recommendations provided 
by the manufacturer of the filter regulator during mainte-
nance and cleaning.

10.6  Comments on the scissors' sliding areas

Due to the design principles, very strong forces are pres-
ent on the sliding surfaces of the scissors. These forces 
can lead to grooving in the sliding surfaces. They will not 
affect the operation of the dryer.
The maintenance intervals described in 10.1 and other 
manuals must be adhered to.

10.7  Disposal

Dispose of used items at the nearest environmental pro-
tection facility for recycling.

11. Spare parts

The following spare parts are the most common ones for 
the SingleHeater IR-units.

Part 

Part nr.

1 Fan 

202024

2 Filter 

103055

IR lamp 790 mm 3 kW 

102701

Lamp holder 

109790

Temp switch 

126043

Distance sensor 

195266

 Pyrometer 

750231

Reflector E790 Gold foil 

102696

Reflector E790 Net 

193646

Reflector E790 Glass 

716238

Printed Circuit Board (PCB) 

750321

Solid State Relay (SSR) 

750227

 Display 

750220

Spare parts for Herkules working platform, see appendix 
1: 761-054_PNTS-77

For other spare parts, please contact:

Hedson Technologies AB

 

Box 1530 
462 28 Vänersborg 
Sweden
Tel. 

+46 (0)521 28 12 30

Fax 

+46 (0)521 28 12 31

E-mail:   [email protected] 

12. Safety Inspections

The safety inspection is required to ensure operational 
safety of the dryer.
The following must be performed:

Before commissioning the dryer at the manufac-
turer’s, use the Regular Safety Inspection form, see
12.1.

After the initial commissioning, check at regular
intervals as per chapter 10. Use the Regular Safety
Inspection form, see 12.1.

Enter the condition of the lifting platform in a sepa-
rate copy of the inspection log and attach it to the
operating manual.

Note!

 The regular safety checks must be performed by a 

suitably trained person. It is advisable to also implement 
maintenance at the same time. 

Note! 

After a replacement part has been attached during 

service to the lifting equipment always perform a Regular 
safety inspection
Contact Hedson Technologie's customer service depart-
ment if you have any further questions.
E-mail [email protected]

5

6

3

Glass

3

6

4

4

2

1

Net

Summary of Contents for IRT System Series

Page 1: ...196349 rev 1 Hedson Technologies AB 2018 IRT Dryer Siemens Leading Edge Protection EN Operation Manual original language...

Page 2: ...wner 5 5 Assembly instruction 5 6 Basic instruction for operation 5 7 Program mode 8 8 Extended usage information 9 9 Settings mode 9 10 Maintenance and Service 12 11 Spare parts 14 12 Safety inspecti...

Page 3: ...ounted on the lifting platform 1 Safety instructions 1 1 Operator s duty of care The IRT Siemens Leading Edge Protection Dryer is designed and built after a hazard assessment was con sidered and follo...

Page 4: ...king under the raised working platform and during its lifting and lowering movements is not permitted 3 Product description The IRT Siemens Leading Edge Protection Dryer is a maneuverable infrared dry...

Page 5: ...ir only A filter regulator must only be installed in the air supply line air filter and water separator 6 Basic instruction for operation Move the dryer to the site where you want to use it This can o...

Page 6: ...amps Control panel 1 The lights turn green when the correct distance obtained between IR lamps and object This distance must be checked before the IR lights turned on During operation with IR lamps th...

Page 7: ...ered This is normally not a part of the everyday usage To enter the settings mode press both arrow keys when you turn the main switch to position 1 Read chapter 9 for more information 6 8 Program inte...

Page 8: ...is finished If this happens check the cooling system of the con trol unit fan filter or ambient temperature 3 Paint Temperature Alarm Also called Process alarm see 8 2 Option if pyrometer is used 4 Fi...

Page 9: ...ram is terminated In case of process alarm check if the temperature measuring device pyrometer is aligned correctly on the surface to be dried and that it is not registering unwanted material temperat...

Page 10: ...o select no yes Press select to confirm 9 4 6 7 Basic PIN Code You can change the PIN code to prevent unauthor ized access to the basic setting as described in table in chapter 9 4 To do this use the...

Page 11: ...t 4 Cassette IR Test The IR cassette lamps output I light up Check that all the IR lamps are lit For safety reasons this test is limited to 10 seconds Press enter or next to continue Test 5 Ventilator...

Page 12: ...uitably trained personnel Do not use running water or flammable liquids for clean ing Abide by the following points to ensure a long service life and continuous operation of the dryer Only original sp...

Page 13: ...round the lamp until the fit ting is completed 1 Loosen the mounting screws on both end cov ers 2 Loosen both lamp end protections 3 Pull the protection out of the slide The screws for the lamp holder...

Page 14: ...st environmental pro tection facility for recycling 11 Spare parts The following spare parts are the most common ones for the SingleHeater IR units Part Part nr 1 Fan 202024 2 Filter 103055 3 IR lamp...

Page 15: ...s to the zero position when released Fall arrester function Emergency release status Air bellows status Supporting structure status Function test Lifting lowering Function test Lifting lowering with l...

Page 16: ...lowing standard s or other normative document s EN 61000 6 4 Electromagnetic Compatibility Generic Emission Standard EN 61000 6 3 Electromagnetic Compatibility Generic Immunity Standard EN 60204 1 Saf...

Page 17: ...appendix 1 761 054_PNTS 77 Electrical diagram for IRT Siemens Leading Edge Protection Dryer equipment is found in the appendix 2 15 Weights and Dimensions The overall weight is 665 kg Dimensions as b...

Page 18: ...sette tripped Check fans filters hoses and ambient tempera ture Reset by pressing the temp switch button Lifting malfunction Maintenance unit manometer without mains pressure Ensure the mains pressure...

Page 19: ...70 196349 rev 1...

Page 20: ...53 42 00 Telefax 46 0 40 43 29 01 www hedson com HEDSON TECHNOLOGIES AB Box 1530 SE 462 28 V nersborg Tel 46 0 40 53 42 00 Telefax 46 0 521 669 09 www hedson com Hedson Technologies 2017 The manufact...

Reviews: