78
Very slow leak
somewhere in the
system.
Check and tighten any
leaking fittings.
Contact your
Local Dealer
.
Someone is taking hot
water from the system
when needed.
Add water.
Refer to
“Water Level Maintenance.”
Someone has
accidentally opened
a valve and not told
anyone.
Add water.
Refer to
“Water Level Maintenance.”
Leaking water line.
Fix leak in water line.
Contact your
Local Dealer
.
Bladder is leaking.
Replace bladder.
Refer to
“Bladder.”
Door hoses are leaking.
Replace door hoses.
Refer to
“Firebox Door Hoses and
Elbows.”
Bladder gate valve needs
adjusting.
Adjust and tighten
gate valve.
Refer to
“Bladder Gate Valve and
Bladder Hose.”
Hose clamps are leaking.
Tighten hose clamps.
Contact your
Local Dealer.
Smoke from
chimney is an
annoyance.
Chimney is not
high enough.
Add Chimney
Extension.
Refer to
“Chimney Extension(s).”
Improper location of
furnace (trees, buildings,
winds, neighbors).
Possibly relocate
furnace. Contact local
dealer.
Contact your
Local Dealer.
Built up creosote is
burning off firebox
surface. Wood pieces
are too small - too much
surface area.
Maintain hot fire.
Refer to
“Wood.”
PROBLEM
CAUSE
SOLUTION
PROCEDURE
Summary of Contents for 400-4S
Page 1: ...Outdoor Furnaces TM SAVE THESE INSTRUCTIONS...
Page 10: ...5 HEATMOR Stainless Steel Outdoor Furnace Model 400 4S Chapter 1...
Page 73: ...68...
Page 88: ...83 PROBLEM CAUSE SOLUTION PROCEDURE...
Page 92: ...87 Outdoor Furnaces...
Page 93: ...88 NOTES...
Page 94: ...89 wiring diagram...
Page 95: ...90 Revised Manual on 07 11 12...