11
MINIMUM CLEARANCE SEPARATION SPECIFICATIONS
The HEATMOR
TM
furnace, is certified to be installed outside, away from other buildings. Please observe the
following “Clearance to Combustibles” guidelines. If you have further questions, which are not addressed
in this Operators Manual, please contact your local dealer for further information.
-To HEATMOR
TM
Stainless Steel Outdoor Furnace Back
96 Inches
-To HEATMOR
TM
Stainless Steel Outdoor Furnace Top
18 Inches
-To HEATMOR
TM
Stainless Steel Outdoor Furnace Front
48 Inches
-To HEATMOR
TM
Stainless Steel Outdoor Furnace Chimney
96 Inches
-To HEATMOR
TM
Stainless Steel Outdoor Furnace Sides
6 Inches
-Do not store combustible liquids or materials near the furnace.
-It is not recommended to install the furance in any form of building.
Before installing your HEATMOR
TM
Stainless Steel Outdoor Furnace, if in the United States, always check
any and all applicable state and local regulations and inform your insurance agent.
Before installing your HEATMOR
TM
Stainless Steel Outdoor Furnace, if in Canada, always check any and all
applicable Provincial and Municipal regulations and inform your insurance agent.
HEATMOR
TM
Inc. strongly recommends not installing a HEATMOR
TM
Stainless Steel Outdoor Furnace within
50 feet of any flammable structure.
A HEATMOR
TM
Stainless Steel Outdoor Furnace should be located with consideration to your neighbor’s
property and in accordance with local ordinances. Refer to the “Best Burn Practices” for further operating
considerations.
HEATMOR
TM
Stainless Steel Outdoor Furnaces are not designed or certified to be located in densely populated
areas.
CHAPTER 5
Summary of Contents for 400-4S
Page 1: ...Outdoor Furnaces TM SAVE THESE INSTRUCTIONS...
Page 10: ...5 HEATMOR Stainless Steel Outdoor Furnace Model 400 4S Chapter 1...
Page 73: ...68...
Page 88: ...83 PROBLEM CAUSE SOLUTION PROCEDURE...
Page 92: ...87 Outdoor Furnaces...
Page 93: ...88 NOTES...
Page 94: ...89 wiring diagram...
Page 95: ...90 Revised Manual on 07 11 12...