12
CHAPTER 6
WARNINGS AND PRECAUTIONS
Please read the following list of cautions, warnings and dangers before installing and operating your
HEATMOR
TM
Stainless Steel Outdoor Furnace. If you have any questions or concerns regarding any of the
following cautions, warnings or dangers or instructions in this Operations and Maintenance manual, please
contact your local dealer.
Familiarize yourself with the “Best Burn Practices” located on the inside front cover.
Installation
Installation should be performed by a qualified installer and will comply with all the requirements of
the authority having jurisdiction over the installation.
1) The HEATMOR
TM
furnace is design fvor outside installation, away from other buildings.
2) Please observe the following “Clearance to Combustibles” guidelines.
To unit back = 96 inches
To unit sides = 6 inches
To unit front = 48 inches
To chimney = 96 inches
To unit top = 18 inches
3) Before installing the furnace, always check any and all applicable state, provincial, and local
regulations.
4) HEATMOR
TM
strongly recommends not installing a HEATMOR
TM
Stainless Steel Outdoor Furnace
within 50 feet of any flammable structure.
5) A HEATMOR
TM
Stainless Steel Outdoor Furnace should be located with consideration to your
neighbor’s property and ina ccoradance with local ordinances. HEATMOR
TM
Stainless Steel Outdoor
Furnace. are not designed to be located in densely populated areas.
6) HEATMOR
TM
suggests the use of brass fittings when installing the unit.
7) Before installing the HEATMOR
TM
furnace, contact and inform your insurance agent.
8) The HEATMOR
TM
Outdoor Furnace is to be installed on a concrete base only. Any attempt to place
the furnace on any other surface may void the warranty.
9) Do not connect the HEATMOR
TM
furnace to the chimney of any existing heating system.
10) This unit was not designed, nor is it recommended, for use as a stand-alone heating system. A
back up source of heat must be in place to prevent the outdoor furnace from freezing and to provide
supplementary heat for the heated buildings.
11) Do not pressurize the HEATMOR
TM
Outdoor Furnace. This unit is designed to operature under
atmospheric pressure only.
12) Place the in-line fill/drain assembly in a location where the drained contexts of the HEATMOR
TM
will
not cause damage to the surrounding areas or it’s contents.
Summary of Contents for 400-4S
Page 1: ...Outdoor Furnaces TM SAVE THESE INSTRUCTIONS...
Page 10: ...5 HEATMOR Stainless Steel Outdoor Furnace Model 400 4S Chapter 1...
Page 73: ...68...
Page 88: ...83 PROBLEM CAUSE SOLUTION PROCEDURE...
Page 92: ...87 Outdoor Furnaces...
Page 93: ...88 NOTES...
Page 94: ...89 wiring diagram...
Page 95: ...90 Revised Manual on 07 11 12...