HEAT
SOURCE
UH6 - 230v Thermostat Range
OFF ON
1
2
3
4
5A FUSE
MAINS SUPPLY
TIMECLOCK
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
UFH
RAD
L
L
N
N
L
N
E
LS
LS
LR
LR
L
N
E
L
N
E
L
L
N S/L
HEAT
UFH PUMP
DELAY
SETTING
L
L
N
N
L
L
N
N
L
L
N
N
L
L
N
N
L
L
N
N
L
N S/L
L
N S/L
L
N S/L
L
N S/L
L
N S/L
CONNECT UP TO 4 ACTUATORS
PER ZONE, AS SHOWN HERE
LS & LR CONNECTIONS
ARE VOLT FREE
Edge
Slimline
DS-SB
Touch V2
neoStat
L N SL RT- RT+
L N A1 A2 - RT
L N A1 A2 - RT1 A
L N A1A2 - RT1 RT2
B
EARTH
L N A1 A2 - RT1 A B
This equipment should be installed by an appropriately qualified/registered electrician.
Fully read the instructions for proper wiring before applying power.
The warranty does not cover damage from improper wiring or installation.
A
H
Wiring Centre
NEUTRAL
EARTH
LIVE
SWITCH LIVE
END SWITCH
or HEAT ENABLE
WIRING KEY
MAINS
SUPPLY
15
UFH
PUMP