background image

Wiring Centre

UFH

PUMP

Model:

 

UH6

Model:

 

UH6

     OFF           ON

 

                  1

 

                  2

 

 

        3

 

 

        4

5A FUSE

MAINS SUPPLY

TIMECLOCK

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

UFH

RAD

L

L

N

N

L

N
E

LS
LS
LR
LR

L

N

E

L

N

E

L

L

N S/L

HEAT

UFH PUMP

DELAY

SETTING

L

L

N

N

L

L

N

N

L

L

N

N

L

L

N

N

L

L

N

N

HEAT

SOURCE

L

N S/L

L

N S/L

L

N S/L

L

N S/L

L

N S/L

CONNECT UP TO 4 ACTUATORS

PER ZONE, AS SHOWN HERE

LS & LR CONNECTIONS

ARE VOLT FREE

EARTH

NEUTRAL

EARTH
LIVE
SWITCH LIVE

END SWITCH

or HEAT ENABLE

WIRING KEY

This equipment should be installed by an appropriately qualified/registered electrician.

Fully read the instructions for proper wiring before applying power.

The warranty does not cover damage from improper wiring or installation.

RADIATOR

ZONE VALVE

(WITH END

SWITCH)

UH6 - NEOSTAT 6 ZONES WITH TIME CLOCK 

(5 X UFH, 1 X RADIATOR ZONE)

MAINS

SUPPLY

N A1 A2 - RT

L

14

UFH Zone

UFH Zone

UFH Zone

UFH Zone

Radiator Zone

UFH Zone

N A1 A2 - RT

L

N A1 A2 - RT

L

N A1 A2 - RT

L

N A1 A2 - RT

L

N A1 A2 - RT

L

Summary of Contents for UH6

Page 1: ...Model UH6 Compact Wiring Centre...

Page 2: ...manifold pump output designed for use with underfloor heating systems is also included as standard UH6 Installation Manual When zones 1 5 are being used for underfloor heating zones zone 6 can be used...

Page 3: ...stallation Removing from Din Rail Slide Din Rail release clip down 1 2 Release the base then slide up Din Rail UH6 Top Slide top section down on to Din Rail 1 2 Push until Click Din Rail Mounting The...

Page 4: ...hen there is a call for heat Delay Setting Switches Heat UFH Pump delay When there s a demand it is possible to set a timed delay before activating the Pump Heat outputs OFF ON 1 2 OFF ON 1 2 OFF ON 1...

Page 5: ...nnections correspond to the thermostat zone wired in at the top of the UH6 When there s a demand from this zone all four sets of L N connections are activated the corresponding zone LED will light up...

Page 6: ...er depending on the zone number being wired The cable size example on the left shows the longest earth cable length from zone 6 on the far right to the earth connection block on the far left Below sho...

Page 7: ...n here Push into the groove to hold cable in position Connect the earth cable from the mains supply into the first earth connection on the UH6 earth terminal block Clamp the insulated part of the cabl...

Page 8: ...using non programmable thermostats connect the Time Clock cable as shown here The earth cable from the time clock goes directly in the earth slot Wire the thermostat connections as shown here connect...

Page 9: ...Installing UH6 Front Module Locate the UH6 front module on to the back plate ensuring each cable aligns with the slots on the front panel Turn the four screws 90 clockwise to lock the front module in...

Page 10: ...strands open the cable clamp before inserting the cable To open the cable clamp insert a small screwdriver into the slot underneath the cable entry and push on the spring loaded button the cable entr...

Page 11: ...pper L connection As shown in image 4 Repeat this process for all other zones any outputs that are not needed can be ignored Each zone output has connections for up to 4 x 230v actuators 1st Actuator...

Page 12: ...into the E connection Next insert the Neutral wire into the N connection as shown here Heat This is the voltfree heat output for the system and should be wired to your heat source Connections are mark...

Page 13: ...o place the clear front cover on to the UH6 line up the front cover with the slots along the top bottom edge then slide the front on Turn the two screws 90 clockwise to lock the front cover in positio...

Page 14: ...RT EARTH NEUTRAL EARTH LIVE SWITCH LIVE END SWITCH or HEAT ENABLE WIRING KEY This equipment should be installed by an appropriately qualified registered electrician Fully read the instructions for pr...

Page 15: ...CTIONS ARE VOLT FREE EARTH NEUTRAL EARTH LIVE SWITCH LIVE END SWITCH or HEAT ENABLE WIRING KEY This equipment should be installed by an appropriately qualified registered electrician Fully read the in...

Page 16: ...S PER ZONE AS SHOWN HERE LS LR CONNECTIONS ARE VOLT FREE Edge Slimline DS SB Touch V2 neoStat L N SLRT RT L N A1A2 RT L N A1A2 RT1 A L N A1A2 RT1 RT2 B EARTH L N A1A2 RT1 A B This equipment should be...

Page 17: ...Model UH6 Model UH6 16 System Configuration UH6 Wiring Centre Title Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone Type Under Floor Heating Radiator Title ENGINEER TO COMPLETE ON INSTALLATION...

Page 18: ...Wiring Centre 17 Notes...

Page 19: ...Model UH6 Model UH6 18 Notes...

Page 20: ...com thermostats NeoStat v2 PDF FAQ VIDEO Want More Information Call our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com DS SB Heatmiser UK...