NASIM REAR DIRECT VENT DECORATIVE GAS APPLIANCE
C. FRAMING
Figure 3 shows a typical framing of this appliance using combustible materials. Figure 4 shows the mantel heights for mantel
projections. All required clearances to combustibles must be adhered to.
Figure 3 - Framing
Figure 4 - Mantel Heights
CAUTION:
Wear gloves and safety glasses for protection.
CAUTION:
Provide adequate clearances around the air
openings into the combustion chamber and
adequate accessibility clearances for servicing and
proper operation.
D. SETTING THE APPLIANCE
POSITIONING THE APPLIANCE
This appliance may be placed on a smooth combustible or noncombustible continuous, flat surface. When the appliance
is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be
installed on a metal or wood panel extending the full width and depth of the appliance. Slide the appliance into
position and level the appliance from side-to-side and front-to-back. Shim with noncombustible material as necessary.
Secure the appliance by bending out the nailing flanges on each side of the appliance and nail to framing. The nailing
flanges have been positioned 5/8 inch back from the front of the appliance to allow the addition of drywall.
WARNING!
To prevent contact with sagging or loose insulation, the appliance must not be installed against vapor barriers
or exposed insulation. Localized overheating could occur and a fire could result.