09-02
21
30532 Rev D
NASIM REAR DIRECT VENT DECORATIVE GAS APPLIANCE
H. FINISHING
Combustible Finishing Material
Materials made of or surfaced with wood, compressed
paper, plant fibers, plastics, or any material capable of
igniting and burning, whether flame proofed or not, plastered
or unplastered (this includes drywall) are considered to be
combustible.
Noncombustible Finishing Material
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or combination thereof, or have a
UL Fire rating of Zero (0).
High Temperature Sealant Material
Sealants that will withstand high temperatures: General
Electric RTV103 (Black) or equivalent; Rutland, Inc.
Appliance Mortar #63 or equivalent.
A high temperature sealant, 1/8 minimum width bead, must
be used to close off gaps between the appliance and the
facing to prevent cold air leaks. See Figure 40.
A combustible mantel may be installed at a minimum of
36 above the base of the appliance.
Figure 40
Finishing Materials
1. ATTACHING THE HOOD
The hood must be attached or a fire hazard may result.
Simply slide the hood into the three clips above the
appliance opening. See Figure 39.
2. GLASS AND SCREEN REMOVAL
See page 27 of this manual.
Figure 41
Hood Placement
WARNING!
Panels and hoods on this appliance cannot, in any
way, be covered as it may create a fire hazard.
All manuals and user guides at all-guides.com