15
Heatilator • HEIR36, HEIR42, HEIR50 Owner’s Manual • 2285-981 Rev. H • 5/15
• Verify that
fi
xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Logs
Frequency:
Annually
By:
Quali
fi
ed Service Technician
Tools needed:
Protective gloves.
• Inspect for damaged or missing logs. Replace as neces-
sary. Refer to Installation manual for log placement instruc-
tions.
• Verify correct log placement and no
fl
ame impingement
causing sooting. Correct as necessary.
Firebox
Frequency:
Annually
By:
Quali
fi
ed Service Technician
Tools needed:
Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
• Replace
fi
replace if
fi
rebox has been perforated.
Control Compartment and Firebox Top
Frequency:
Annually
By:
Quali
fi
ed Service Technician
Tools needed:
Protective gloves, vacuum cleaner, dust
cloths
• Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
• Remove all foreign objects.
• Verify unobstructed air circulation.
Burner Ignition and Operation
Frequency:
Annually
By:
Quali
fi
ed Service Technician
Tools needed:
Protective gloves, vacuum cleaner, whisk
broom,
fl
ashlight, voltmeter, indexed drill bit set, and a
manometer.
• Verify burner is properly secured and aligned with pilot
or igniter.
• Clean off burner top, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
• Replace Glowing embers with new dime-size pieces.
DO NOT
block ports or obstruct lighting paths. Refer
to appliance installation manual for proper ember
placement.
• Verify batteries have been removed from battery back-
up IPI systems to prevent premature battery failure or
leaking.
• Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay.
• Inspect for lifting or other
fl
ame problems.
• Verify air shutter setting is correct. See Installation
Manual for required air shutter setting. Verify air shutter
is clear of dust and debris.
• Inspect ori
fi
ce for soot, dirt and corrosion. Verify ori
fi
ce
size is correct. See Service Parts List for proper ori
fi
ce
sizing.
• Verify manifold and inlet pressures. Adjust regulator as
required.
• Inspect pilot
fl
ame pattern and strength. See Figure 4.1
for proper pilot
fl
ame pattern. Clean or replace ori
fi
ce
spud as necessary.
• Inspect IPI
fl
ame sensing rod for soot, corrosion and
deterioration. Polish with
fi
ne steel wool or replace as
required.
• Verify that there is not a short in
fl
ame sense circuit
by checking continuity between pilot hood and
fl
ame
sensing rod. Replace pilot as necessary.
Figure 4.1 IPI Pilot Flame Patterns