background image

2

Heatilator  • HEIR36, HEIR42, HEIR50 Owner’s Manual  •  2285-981 Rev. H  •  5/15

Listing Label Information/Location

A. Congratulations

Congratulations on selecting a Heatilator gas 

fi

 replace, an 

elegant and clean alternative to wood burning 

fi

 replaces. 

The Heatilator gas 

fi

 replace you have selected is designed 

to provide the utmost in safety, reliability, and ef

fi

 ciency.

As the owner of a new 

fi

 replace, you’ll want to read and 

carefully follow all of the instructions contained in this 
owner’s manual. Pay special attention to all cautions and 
warnings.

This owner’s manual

 

should be retained for future 

reference. We suggest that you keep it with your other 
important documents and product manuals.
The information contained in this owner’s manual, unless 
noted otherwise, applies to all models and gas control 
systems.
Your new Heatilator gas 

fi

 replace will give you years of 

durable use and trouble-free enjoyment. Welcome to the 
Heatilator family of 

fi

 replace products!

Gas and Electric 
Information

Serial Number

Type of Gas

The model information regarding your speci

fi

 c 

fi

 replace can be found on 

the rating plate usually located in the control area of the 

fi

 replace.

Model Number

Not 

Not for 

for use 

use with 

with solid 

solid fuel.

fuel.

((

Ne 

Ne doit 

doit pas 

pas entre 

entre utilise 

utilise avec 

avec un 

un combustible 

combustible solide).

solide).

This 

This appliance 

appliance must 

must be 

be installed 

installed in 

in accordance 

accordance with 

with local 

local codes, 

codes, if 

if any; 

any; if 

if not, 

not, follow 

follow ANSI 

ANSI Z223.1

Z223.1

in 

in the 

the USA 

USA or 

or CAN/CGA 

CAN/CGA B149 

B149 installation 

installation codes. 

codes. 

(Installer 

(Installer l’appareil 

l’appareil selon 

selon les 

les codes 

codes ou 

ou reglements

reglements

locaux 

locaux ou, 

ou, en 

en l’absence 

l’absence de 

de tels 

tels reglements, 

reglements, selon 

selon les 

les codes 

codes d’installation 

d’installation CAN/CGA-B149.)

CAN/CGA-B149.)

Type 

Type of 

of Gas 

Gas 

(Sorte 

(Sorte De 

De Gaz)

Gaz)

::

N

NA

ATURAL

TURAL  GAS

GAS

MADE 

MADE   IN 

IN   USA

USA

Minimum 

Minimum Permissible 

Permissible Gas 

Gas Supply 

Supply for 

for Purposes 

Purposes of 

of Input 

Input Adjustment.

Adjustment.

Approved 

Approved Minimum 

Minimum 

(De 

(De Gaz) 

Gaz) 

Acceptable

Acceptable 0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Maximum 

Maximum Pressure 

Pressure 

(Pression)

(Pression)

  0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Maximum 

Maximum Manifold 

Manifold Pressure 

Pressure 

(Pression)

(Pression)

   

   0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Minimum 

Minimum Manifold 

Manifold Pressure 

Pressure 

(Pression)

(Pression)

   

   0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Model:

Model:

(Modele):

(Modele):

Serial

Serial

(Serie):

(Serie):

ANSI 

ANSI Z21XX-XXXX 

Z21XX-XXXX · 

· CSA 

CSA 2.XX-MXX 

2.XX-MXX   

XXXXXXXX

XXXXXXXX

IN 

IN CANADA

CANADA

ALTITUDE:

ALTITUDE:

0-0000 

0-0000 FT.

FT.

0000-0000FT.

0000-0000FT.

MAX. 

MAX. INPUT 

INPUT BTUH:

BTUH:

00,000

00,000

00,000

00,000

MIN. 

MIN. INPUT 

INPUT BTUH:

BTUH:

00,000

00,000

00,000

00,000

ORIFICE 

ORIFICE SIZE:

SIZE:

#XXXXX

#XXXXX

#XXXXX

#XXXXX

XXXXXXXX

XXXXXXXX

Total 

Total Electrical 

Electrical Requirements: 

Requirements: 000Vac, 

000Vac, 00Hz., 

00Hz., less 

less than 

than 00 

00 Amperes

Amperes

 

 
 

 

Heatilator, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN   55044

Read this manual before operating this appliance. 

Please retain this Owner’s Manual for future reference.

Read the Installation Manual before making any installation or 

fi

 nishing changes.

Welcome  

Brand: ________________________________________________ Model Name: ___________________________

Serial Number: __________________________________________ Date Installed:  __________________________

Appliance Information:

Local Dealer Information

DEALER:

 

Fill in 

your name, address, 
phone and email 
information here and 
appliance information 
below.

Dealer Name: ________________________________________________________

Address: ____________________________________________________________

               ____________________________________________________________

Phone:   _____________________________________________________________

Email:    _____________________________________________________________

Summary of Contents for HEIR36H

Page 1: ...al with party responsible for use and operation OWNER Retain this manual for future reference Contact your dealer with questions regarding installation operation or service Models HEIR36H HEIR36T HEIR...

Page 2: ...De Gaz Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved A...

Page 3: ...liance Certification 6 B Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 9 D Before Li...

Page 4: ...n the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independe...

Page 5: ...Y EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may...

Page 6: ...ualified personnel Hearth Home Technologies suggests NFI certified or factory trained professionals or technicians supervisedby an NFI certified professional www nficertified org B Glass Specification...

Page 7: ...e selector switch on the control module to the OFF position and remove batteries 3 3 Important Safety and Operating Information Clear Space WARNING DO NOT place combustible objects in front of the fir...

Page 8: ...ION 3 B OPERATION DURING A POWER OUTAGE SECTION 3 H Rating Plate Glass Clip Tool Location The rating plate for this model is located underneath the firebox affixed to a tray that must be accessed usin...

Page 9: ...the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO NOT op erate fireplace with fixed glass assembly removed C Fuel Specifications WARNING Risk of Fire or Explosion Appliance mus...

Page 10: ...ce Hot while in operation DO NOT touch Keep children clothing furniture gasoline and other liquids having flammable vapors away DO NOT operate the appliance with fixed glass assembly removed cracked o...

Page 11: ...ge Batteries should not be used as a primary long term power source To Operate Fireplace Using Battery Power DC 1 Access the control cavity of the appliance See Figure 3 2 for location The decorative...

Page 12: ...fireplace on HI and remain so for the initial 10 seconds of operation If the HI LO is switched to the LO position the flame output will automatically drop to the lowest setting after the flame has bee...

Page 13: ...Burner Ignition Operation Annually A Maintenance Frequency and Tasks Decorative Fronts Surrounds Frequency Annually By Homeowner Tools needed Protective gloves stable work surface Assess condition of...

Page 14: ...ner drop cloth and a stable work surface WARNING Risk of Injury Glass installation and re moval must be performed only by a qualified service tech nician CAUTION Handle fixed glass assembly with care...

Page 15: ...s needed Protective gloves vacuum cleaner whisk broom flashlight voltmeter indexed drill bit set and a manometer Verify burner is properly secured and aligned with pilot or igniter Clean off burner to...

Page 16: ...ound the fireplace Film on the glass This is a normal result of the curing process of the paint and logs Glass should be cleaned within 3 to 4 hours of initial burning to remove deposits left by oils...

Page 17: ...ximately 17 in or 1 8 in 3 mm 2 Pilot won t light there is no noise or spark A No power transformer installed incorrectly or depleted batteries Verify that transformer is installed and plugged into mo...

Page 18: ...sensor wire Polish flame sens ing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continuity with a multi meter with ohms set at lowest range...

Page 19: ...trols out of reach of children See your dealer if you have questions Optional Heat Zone Gas Kit An optional Heat Zone Kit is available for your appli ance It must be installed by a qualified service t...

Page 20: ...2283 703 4 Log 4 SRV2284 704 5 Log 5 SRV2284 705 6 Log 6 SRV2284 706 7 Heat Shield Header Qty 2 req 2280 105 8 Heat Shield Valve 2281 153 9 Junction box 4021 013 Y 10 J Box Bracket 2281 154 11 Valve A...

Page 21: ...4 Refractory Left Base SRV2283 711 19 5 Refractory Front Base SRV2283 710 19 6 Refractory Right Base SRV2283 712 19 7 Refractory Right SRV2283 714 19 8 Refractory Back SRV2283 715 Refractory Herringb...

Page 22: ...og 3 SRV2284 703 4 Log 4 SRV2284 704 5 Log 5 SRV2284 705 6 Log 6 SRV2284 706 7 Heat Shield Header Qty 2 req 2281 105 8 Heat Shield Valve 2281 153 9 Junction box 4021 013 Y 10 J Box Bracket 2281 154 11...

Page 23: ...4 Refractory Left Base SRV2284 711 19 5 Refractory Front Base SRV2284 710 19 6 Refractory Right Base SRV2284 712 19 7 Refractory Right SRV2284 714 19 8 Refractory Back SRV2284 715 Refractory Herringb...

Page 24: ...SRV2285 704 5 Log 5 SRV2285 705 6 Log 6 SRV2285 706 7 Heat Shield Header 2282 105 8 Heat Shield Valve 2281 153 9 Junction box 4021 013 Y 10 J Box Bracket 2281 154 11 Valve Assembly Refer to Valve Page...

Page 25: ...Refractory Front Base SRV2285 710 20 5 Refractory Right Base SRV2285 712 20 6 Refractory Back Bottom SRV2285 715 20 7 Refractory Right SRV2285 714 20 8 Refractory Back SRV2285 717 Refractory Herringb...

Page 26: ...P 2166 303 Y 11 4 Flex Ball Valve Assembly 12 302 320A Y 11 5 Jumper Wire 2187 198 Y 11 6 Wire Battery Jumps 10 in 2281 196 Y 11 7 Battery Pack 2166 323 Y 11 8 Grommet 2118 420 11 9 Pilot Assembly NG...

Page 27: ...lass Latch Assembly Qty 2 req 2146 413 Y Glass Latch Assembly Heir 36 Qty 3 req 2155 045 Y Heir 42 50 Qty 4 req Lava Rock 4021 296 Nut 1 4 20 Hex Insert 7000 236 Mineral Wool 050 721 Non Comb Assembly...

Page 28: ...sell directly to consumers Provide model number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Trim Strip Sides...

Page 29: ...______________________________________________ ________________________________________________________________________________ ________________________________________________________________________...

Reviews: