NOVUS TOP DV GAS APPLIANCE INSTALLATION INSTRUCTIONS
2. VERTICAL TERMINATION
a. Clearances
See Figure 14 for clearance information.
b. Vent Lengths
Various venting configurations are shown in
Figures 15-16 from which maximum vent runs
can be determined.
Figure 14
Vertical Termination Clearances
Figure 15
Vertical Termination Vent lengths
Figure 16
Vertical Termination Vent Lengths
WARNING - RISK OF FIRE!
Always maintain minimum air space clearances or
greater around the chimney system. Do not pack
air space with insulation or other material.
WARNING
The horizontal run of vent must have a ¼ rise for
every 1 ft. of run towards the termination. Never
allow the vent to run downward. This could cause
high temperatures and may present a fire hazard.
c. Assembling Chimney Sections
Use only pipe supplied and listed for use with
this appliance. See page 4 for a description
of listed components. See Section 3 on page
13 for instructions on assembling vent
sections.
CAUTION:
For vertically terminated installations, metal tape at
each vent joint will help prevent excess air infiltration
and improve flame appearance. All joints above the
storm collar should be taped and/or sealed with
silicone caulk to prevent water penetration.