background image

02-02

27

28467 Rev I

NOVUS TOP DV GAS APPLIANCE INSTALLATION INSTRUCTIONS

Index

H

High Altitude InstallAtion  14

High Temperature  Sealant  Material

17

Hood  17

Horizontal Installation  3

Horizontal  Termination

Clearances  7

Vent Lengths  7

I

Interior Wall Shield  9

J

Junction Box  16

Junction Box Wiring  16

L

Lava Rock  18

Lighting  Instructions

Electronic Ignition  19

Log Set  18

M

Maintenance Instructions  23

Mantel Heights  6

Minimum Installation (MI) Sections

13

N

Nomenclature  4

Noncombustible  Finishing  Material

17

Noncombustible  Materials    6

O

Odor  22

Optional  Components    25, 26

R

Replacement Parts  26

Rock Wool  18

S

Safety Precautions  2

Seasonal  Checklist    21

Setting the Appliance  6

Slip Sections  14

Space Requirements  5

Standing Pilot Ignition  16, 23

Operation  21

Wiring Diagram  15

Start-up Issues  22

T

Termination Cap Locations  10

Termination  Installation    12

U

Upper Grille Panel  17

Utilities  14

V

Venting  13

Assembling    13

Attach to Appliance  13

Disassembling  Vent  Sections    14

Minimum Installation (MI) Sections

13

Slip Sections - Assembly  14

Through the Wall  9

Vermiculite  18

Vertical Installation  3

Vertical Termination

Chimney Height  12

Clearances    11

Multiple Terminations  12

Vent Lengths  11

Vertical Termination Cap  12

W

Wiring  15

Electronic Ignition  16

Wiring Diagram  16

Junction Box  16

Standing Pilot  15, 16

Wiring Diagram  15

A

Appliance Locations  5

Appliance Preparation  18

Lava Rock  18

Rock Wool  18

Vermiculite  18

Attaching the Hood  17

C

Certification  3

Chase Installation  12

Chimney Assembly  8

Chimney Height  12

Clearances  5

Codes  3

Combustible  Materials    6

Control Access Panel  17, 18

Conversion Kits  21

D

Disassembling  Vent  Sections    14

E

Electronic Ignition  16, 23

Operation  21

Units  19

Wiring Diagram  16

Exterior Wall Hole  9

F

Finishing  17

High Temp Sealants  17

Noncombustible  Materials    17

Firebox Preparation  17

Firestop Spacer Installation  12

Flames

Blue  22

Checking the flame patterns  23

Ghosting  23

Framing  6

Fuel  21

G

Gas Line  15

Gas Line Connection  14

Gas Pressure  15

Glass

Condensation    22

Film  22

Glass and Screen Removal  17

Glass and Screen Replacement  18

Grille Panel Removal  15

All manuals and user guides at all-guides.com

Summary of Contents for GNDC30

Page 1: ...y phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation a...

Page 2: ...nting must not be connected to chimney flue servicing a solid fuel burning appliance or a gas fuel burning appliance 7 NEVER use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or...

Page 3: ...atest edition in the U S A and the CAN CGA B149 Installation Codes in Canada This Novus Series gas appliance has been tested and listed for use in manufactured housing mobile homes These installation...

Page 4: ...de Number B Black Firebox GNDC36LEB EXAMPLE Gas NOVUS Direct Vent Heat Circulating 36 Propane Gas Electronic Ignition appliance with Black Firebox Components Description CS Cap Shield VP TV Vertical T...

Page 5: ...gure 2 Appliance Clearances to Combustible Materials A hearth extension is not required for this appliance L E D O M A B C D E 0 3 C D N G 9 2 3 4 4 3 7 8 85 8 3 3 4 3 1 2 3 3 C D N G 2 3 3 4 7 3 7 8...

Page 6: ...3 H D N G 8 7 1 4 4 3 6 3 This appliance may be placed on a smooth combustible or noncombustible continuous flat surface When the appliance is installed directly on carpeting tile or other combustibl...

Page 7: ...as fuel burning appliance WARNING RISK OF FIRE If you have chosen horizontal termination be sure there are no future obstructions from trees bushes snow drifts etc CAUTION Provisions shall be made to...

Page 8: ...n Never allow the vent to run downward This could cause high temperatures and may present a fire hazard Figure 8 Vent Lengths with Two Elbows Figure 9 Vent Lengths with Three Elbows Note Horizontal ru...

Page 9: ...national codes and not be easily blocked or obstructed If the hole being penetrated is of noncombustible materials a 9 diameter hole is acceptable Note Exterior wall thickness must be a minimum of 4 t...

Page 10: ...6 feet 1 8m minimum J Clearance to non mechanical air supply inlet into building or the combustion air inlet to any other appliance 12 inches 30 cm minimum K Clearance to mechanical air supply inlet...

Page 11: ...aterial WARNING The horizontal run of vent must have a rise for every 1 ft of run towards the termination Never allow the vent to run downward This could cause high temperatures and may present a fire...

Page 12: ...ter vent Figure 17 Installing the Firestop Spacer e Chase Termination Installation Figure 18 and 19 and Table 1 specify minimum chimney heights for various pitched roofs These chimney heights are nece...

Page 13: ...into the outer flue of section B See Figure 20 Once both inner and outer flues are started press section A into section B firmly until all lances have snapped into place Tug slightly on section A to...

Page 14: ...utoff valve The incoming gas line should be piped into the valve compartment and connected to the 1 2 FIP connection provided on the manual shutoff valve All connections must be tightened and checked...

Page 15: ...C D N G 0 3 H D N G 0 3 C D N G m m 6 5 2 n i 1 0 1 m m 3 4 2 n i 6 9 0 e z i S e c i f i r O s a G e n a p o r P m m 0 5 1 n i 9 5 0 n m u l o C r e t a W s e h c n i s e t a c i d n i Table 2 Gas In...

Page 16: ...o a thermostat If connecting a 24V thermostat not supplied disconnect the black wire from the transformer at the ignition control Connect the thermostat wires between the ignition control and the blac...

Page 17: ...will withstand high temperatures General Electric RTV103 Black or equivalent Rutland Inc Appliance Mortar 63 or equivalent A high temperature sealant 1 8 inch wide minimum must be used to close off g...

Page 18: ...but does not cover the holes in the burner pan This will provide the glowing embers look See Figure 37 Figure 36 Placing the Vermiculite and Lava Rock top logs removed for clarity Figure 37 Placing th...

Page 19: ...P Read the safety information above on this label 2 Turn wall switch to the OFF position 3 This appliance is equipped with an ignition device which automatically lights the burner Do not try to light...

Page 20: ...ANCE 1 Turn wall switch to the OFF position or set thermostat to lowest setting 2 Open the control access panel 3 Turn manual shutoff valve to CLOSED Wait five minutes to clear out any gas Then smell...

Page 21: ...decide to shut down the appliance for a long period of time a Turn all wall switches to OFF b Turn pilot knob on valve to OFF c Turn the gas line to CLOSED Lighting the Appliance During Regular Use Tu...

Page 22: ...l B 2 o t n i g e b l l i w s e m a l f e h t d n a n o i t a r e p o l a m r o n f o t l u s e r a s i s i h T n r u b o t d e w o l l a s i e c n a i l p p a e h t s a w o l l e y 3 e c n a i l p p...

Page 23: ...re cleaning 2 CHECKING THE FLAME PATTERNS Visually check the flame of the burner periodically making sure the flames are steady not lifting or floating The flame color should be blue with yellow tips...

Page 24: ...THE GLASS See Figure 44 Never operate this appliance without the glass properly secured in place or if the glass if broken or chipped In the event of glass breakage carefully remove the glass frame Th...

Page 25: ...ote Control Standing Pilot RCT MLT HTL Multi Function Remote Control SMART STAT HTL Remote Control with Thermostat Control SMART BATT HTL Battery operated Remote Control with Thermostat Control GP30 C...

Page 26: ...1 1 1 3 4 0 8 6 2 3 0 8 6 2 2 0 8 6 2 6 3 y l b m e s s A n e e r c S 3 3 y l b m e s s A n e e r c S 0 3 y l b m e s s A n e e r c S 1 1 1 4 2 1 7 2 2 1 1 7 2 2 0 1 7 2 2 6 3 e m a r F w s s a l G c...

Page 27: ...s 14 Minimum Installation MI Sections 13 Slip Sections Assembly 14 Through the Wall 9 Vermiculite 18 Vertical Installation 3 Vertical Termination Chimney Height 12 Clearances 11 Multiple Terminations...

Page 28: ...afting caused by tight sealing construction of the structure air handling devices such as exhaust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating...

Reviews: