7065-144D • 20 August, 2018
39
Heatilator EcoChoice WINS18
www.heatilator.com
Figure 39.2
Cast Iron Flue Located on Appliance
Drill through all 8 countersunk
locations
B. Securing Stove Pipe/Liner to Flue Collar
1.
There are 4 already drilled holes in the flue collar 90
degrees apart. Attach the flue collar to the stove pipe/
liner. If the seal is questionable use high temperature
sealant such as stove mastic (
Figure 39.1).
2.
Attach gasket to bottom side of flue collar with a thin
coat of silicone.
Flue Collar
Stove Pipe/Liner
Gasket
Figure 39.1
C. Optional Offset Adapter Installation
In some installations the flue collar and stove pipe/liner do
not always align properly. This situation may be remedied
by using the optional offset adapter. See Appliance
Dimensions page for the amount of distance this accessory
can telescope between the flue collar and stove pipe/liner.
1.
Remove the cast iron flue collar from the appliance
and flip it upside down. Using the larger #7 drill bit
supplied, drill through all 8 countersunk locations
(
Figure 39.2).
2.
Slide the gasket over the flue collar and attach it to the
offset adapter using the 8-32 flathead screws provided
(
Figure 39.3).
3. Adjust the offset adapter to desired distance. Drill holes
through the lower chamber as shown in
Figure 39.4
using the small drill bit #26 provided.
4. Cut the gasket to the proper length and slide in
between the upper and lower chambers centered on
the screw holes. Attach the upper and lower chambers
with screws provided (
Figure 39.5)
.
5. Repeat the process on the bottom side.
Figure 39.3
Figure 39.4
Once distance is established, drill holes
and secure both chambers together.
Figure 39.5