The blower will turn on/off automatically when set to
AUTO
(Figure 15.1)
.
2.
When set to MANUAL, the fan will turn on/off only
when you turn it on or off. This setting over-rides the
internal snap disc.
3. Blower Controls are located on bottom left of
appliance.
Figure 15.1
1. Initial (cold) startup:
Open both controls fully by
raising the Burn Rate Air Control all the way up until
it stops and push the Start-up Air Control back until it
stops.
The blower tends to cool the appliance. Leave
the blower off until the burn is well established, i.e., 30
minutes.
2. High Burn Setting:
Both controls are open. Burn Rate
Air Control is pulled up and the Start-up Air Control is
fully pushed in. Blower may remain on.
3. Medium High Burn Setting*:
Burn Rate Air Control
is closed then opened to 1 inch (pull up )to fully open.
Blower may remain on.
4. Medium
Low Burn Setting*:
Burn Rate Air Control
is closed then opened to 1/4 inch to 1/2 inch. Leave
the blower off until the burn is well established, i.e., 30
minutes.
5. Low Burn Setting*:
Burn Rate Air Control is closed.
Leave the blower off until the burn is well established,
i.e., 30 minutes.
When reloading the appliance, raise the Burn Rate
Air Control all the wall to the High setting for 5 to 15
minutes before setting to the desired burn rate.
M. Blower Control Box & Snap Disc Operating
Instructions
N. Blower Operating Instructions
*NOTE:
For burn settings 3 to 5 the Start-up Air Control
needs to be pushed in (Open) then pulled forward
to activate the Automatic Combustion Control
(ACC).
NOTE:
For maximum efficiency and lowest emissions,
when operating the blower in either the automatic
or manual setting for the low and medium low
burn settings leave the blower off until the burn is
well established, i.e., 30 minutes.
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostat on, then adjusting back towards “OFF” as far
as possible without turning the blower off. For a low
blower speed, turn the control knob clockwise as far as
possible
O. Opacity (Smoke)
This is the measure of how cleanly your appliance is
burning. Opacity is measured in percent; 100% opacity is
when an object is totally obscured by the smoke column
from a chimney, and 0% opacity means that no smoke
column can be seen. As you become familiar with your
appliance, you should periodically check the opacity. This
will allow you to know how to burn as nearly smoke-free as
possible (goal of 0% opacity).
When burning your first fire, you will experience smoke
and odor from the appliance resulting from the curing
of paint and burning off of any oils remaining from
manufacturing.
OPEN WINDOWS DURING INITIAL BURN TO
DISSIPATE SMOKE AND ODORS!
•
O
dors may be irritating to sensitive individuals.
•
Smoke detectors may activate.
CAUTION