Heatilator • Caliber CD Series • 4040-263 Rev M • 06/08
32
F. Install Vertical Termination Baf
fl
e
•
Remove the glass (refer to Section 14.J.) to access the
fi
rebox and 5 in. inner
fl
ue.
•
Fold the baf
fl
e (Figure 7.17) to an approximate 90°
angle (see Figure 7.18).
•
Squeeze the open end of the bent baf
fl
e with one
hand. Insert the baf
fl
e bent side up into the inner
fl
ue
so that the bottom of the baf
fl
e is above the bead on
the inside of the collar. See Figure 7.19.
•
Release pressure on the baf
fl
e so that it is wedged
against the sides of the
fl
ue collar. See Figure 7.20.
•
Replace the glass (refer to Section 14.J.).
•
Start the appliance.
Note:
For vertically terminated installations only.
Figure 7.17 Flat Baf
fl