Heatilator  •  ADI-ZC-FB  •  2032-900  Rev. E  •  8/05

2

These units 

MUST

use one of the vent systems

described in the Installing the Fireplace section of
the

Installers Guide

.

NO OTHER 

vent systems or

components 

MAY BE USED.

This gas fireplace and vent assembly 

MUST

be

vented directly to the outside and 

MUST NEVER 

be

attached to a chimney serving a separate solid fuel
burning appliance. Each gas appliance 

MUST USE

a separate vent system. Common vent systems are

PROHIBITED

.

INSPECT

the external vent cap on a regular basis to

make sure that no debris is interfering with the air
flow.

The glass door assembly 

MUST

be in place and

sealed, and the trim door assembly 

MUST

be in

place on the fireplace before the unit can be placed
into safe operation.

DO NOT OPERATE 

this appliance with the glass

door removed, cracked, or broken. Replacement of
the glass door should be performed by a licensed
or qualified service person. 

DO NOT 

strike or slam

the glass door.

The glass door assembly 

SHALL ONLY 

be

replaced as a complete unit, as supplied by the gas
fireplace manufacturer. 

NO SUBSTITUTE 

material

may be used.

DO NOT USE 

abrasive cleaners on the glass door

assembly. 

DO NOT ATTEMPT 

to clean the glass

door when it is hot.

Turn off the gas before servicing this appliance. It is
recommended that a qualified service technician
perform an appliance check-up at the beginning of
each heating season.

Any safety screen or guard removed for servicing
must be replaced before operating this appliance.

DO NOT 

place furniture or any other combustible

household objects within 36 inches of the fireplace
front.

READ

and

UNDERSTAND 

all instructions carefully

before starting the installation. 

FAILURE TO

FOLLOW

these installation instructions may result

in a possible fire hazard and will void the warranty.

Prior to the first firing of the fireplace, 

READ

the

Using Your Fireplace section of the 

Owners Guide

.

DO NOT USE 

this appliance if any part has been

under water. Immediately 

CALL 

a qualified service

technician to inspect the unit and to replace any part
of the control system and any gas control which has
been under water.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be 

PERFORMED

by a

qualified service person. The appliance and venting
system should be 

INSPECTED

before initial use

and at least annually by a professional service
person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding
material, etc. It is 

IMPERATIVE 

that the unit’s

control compartment, burners, and circulating air
passageways

BE KEPT CLEAN 

to provide for

adequate combustion and ventilation air.

Always

KEEP

the appliance clear and free from

combustible materials, gasoline, and other
flammable vapors and liquids.

NEVER OBSTRUCT 

the flow of combustion and

ventilation air. Keep the front of the appliance

CLEAR

of all obstacles and materials for servicing

and proper operations.

Due to the high temperature, the appliance should
be

LOCATED 

out of traffic areas and away from

furniture and draperies. Clothing or flammable
material

SHOULD NOT BE PLACED 

on or near the

appliance.

Children and adults should be 

ALERTED

to the

hazards of high surface temperature and should

STAY AWAY 

to avoid burns or clothing ignition.

Young children should be 

CAREFULLY SUPERVISED

when they are in the same room as the appliance.

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

SAFETY AND WARNING INFORMATION

!

!

Summary of Contents for ADI-ZC-FB

Page 1: ...H APPLIANCE FOR FUTURE REFERENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 This appliance is only for use wi...

Page 2: ...ce front READ and UNDERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warran...

Page 3: ...System 9 Step 2 Positioning Leveling and Securing the Insert 13 Step 3 The Gas Control Systems 13 Step 4 The Gas Supply Line 13 Step 5 Gas Pressure Requirements 14 Step 6 Wiring the Appliance 14 Wiri...

Page 4: ...ed in accordance with local codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSAC22 1 Canadian Electric Code in Canada These models...

Page 5: ...EXTEN SION IF PRESENT MUST COMPLY WITH EI THER OF THE FOLLOWING 1 THE SOLID FUEL BURNING FIREPLACE MANUFACTURER S SPECIFICATION OR 2 LOCAL BUILDING CODES REQUIRED BY AUTHORITY HAVING JURISDICTION WAR...

Page 6: ...R EXHAUST STARTING COLLAR ON OFF SWITCH OPTIONAL 3 SIDED ADI ZC FB MINIMUM FIREPLACE SIZE LOCATION Inches Millimeters A Front Width 30 7 8 784 B Rear Width 25 5 8 651 C Depth 15 381 Height 19 1 2 495...

Page 7: ...the maximum vertical rise is 50 feet These dimensions are measured from the starting collars of the unit to the end of the last section of vent pipe See dimension V in Figure 3 Vent System Approvals...

Page 8: ...E THE ROOF TOP THESE MINIMUM HEIGHTS ARENECESSARYINTHEINTEREST OF SAFETY SEE THE FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMINATION CAP IS AT LEAST 2 FEET FROM A VER TICAL WALL AND 2 FEET...

Page 9: ...THE INLET AIR COLLAR OF THE UNIT AND EITHER ATTACHED TO THE INLETAIRCOLLAROFTHETERMINATIONCAP OR TERMINATED IN THE CHIMNEY This option shows both exhaust and inlet air vent pipes attached to the adapt...

Page 10: ...KING HANDLE SLIDING PLATE STAINLESS STEEL ADAPTER FOR EXHAUST MUST BE INSTALLED INLET AIR VENT PIPE 3 INCH COLLAR OPTIONAL LINK ZC ADPB For Flashing Class A Pipe TERMINATION CAP SQUARE FLASHING REMOVE...

Page 11: ...building codes to properly size the gas supply line leading to the 1 2 inch 13 mm hook up at the unit This gas fireplace is designed to accept a 1 2 inch 13 mm gas supply line To install the gas supp...

Page 12: ...ECT REMOTE CONTROLS IF AB SENT FOR EXTENDED TIME PERIODS THIS WILL PRE VENT ACCIDENTAL APPLIANCE OPERATION For Standing Pilot Ignition Wiring Appliance Requirements This appliance DOES NOT require 110...

Page 13: ...glass doors JUNCTION BOX VARIABLE SPEED CONTROL TEMPERATURE SENSOR SWITCH WHT GRN BLK BLK 110 120 VAC BLOWER BLOWER RECEPTACLE BLK BLK BLK BLK WHT GROUND WHT BLK BLK BLK REMOTE RECEPTACLE SPEED CONTRO...

Page 14: ...oles in burner top see Figure 12 Space dime size ember pieces about a 1 2 inch apart Never press embers into burner ports DO NOT cover burner ports Place dime size pieces around front and sides of bur...

Page 15: ...ew minutes for the lines to purge themselves of this air Once the purging is complete the appliance will light and will operate normally Subsequent lightings of the fireplace will not require this pur...

Page 16: ...ILOT position turn the control knob counter clockwise to the PILOT position 6 To light the pilot press the control knob and then press the red or black piezo button once every second The piezo makes a...

Page 17: ...vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a...

Page 18: ...copper lead Start the pilot and hold the valve knob in If the millivolt reading is less than 15mV replace the thermocouple b Defective valve If the thermocouple is producing more than 15 millivolts re...

Page 19: ...necessary e Improper vent cap installation Check for proper installation and freedom from debris or blockage 6 Glass soots a Flame impingement Adjust the log set so that the flame does not excessivel...

Page 20: ...itions inadequate ventilation or drafting caused by tight sealing construction of the structure air handling devices such as exhaust fans or forced air furnaces or other causes 5 use of fuels other th...