Heath Zenith SL-5309 Owner'S Manual Download Page 3

3

595-5496-07

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 60 ft. (18.3 m); [varies with 

surrounding temperature]

Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . Up  to  300  Watts  Maximum 

Tungsten

Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST,  AUTO  and  MANUAL 

MODE

Time Delay  . . . . . . . . . 1, 5 or 10 minutes
Sensitivity  . . . . . . . . . . Adjustable
Replacement lamp . . . . T 300W (or less) halogen 120 

VAC

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features in 
products previously sold.

TEST AND ADJUSTMENT

 

Turn on the circuit breaker and light switch.

Maximum 

Range

110°

Maximum

Coverage Angle

NOTE:  Sensor requires about 1 

1

/

2

 minutes to calibrate 

before it will detect motion. When first turned 
on, wait about 1 

1

/

2

 minutes.

Avoid aiming the control at:

•  Objects  that  change  temperature  rapidly,  such  as 

heating  vents  and  air  conditioners.

  These  heat 

sources could cause false triggering.

•  Areas where 

pets or traffic

 may trigger the control.

•  Nearby large, light-colored objects reflecting light may 

trigger the shut-off feature. Do not point other lights 
at the sensor.

60 ft. 

(18.3 m)

The control is most sensitive to motion across it.

 

Least Sensitive 

Most Sensitive

Motion

Sensor

Motion

  Loosen  the  clamp  screw  in 

the sensor ball joint and gently 
rotate the sensor to aim.

  Walk  through  the  coverage 

area  noting  where  you  are 
when the lights turn on. Move 
the  sensor  head  up,  down, 
or  sideways  to  change  the 
coverage area.

  Set SENSITIVITY as needed. 

Too  much  sensitivity  may  in-
crease false triggering.

 

Secure  the  sensor  head 
into position by tightening 
the  clamp  screw.

  Do  not 

overtighten the screw.

 

Set the amount of TIME

 the 

lights stay on after motion is 
detected. It is selectable from 
1, 5, or 10 minutes.

Bottom of Sensor

ON-TIME

10  5  1  TEST

MIN 

MAX

SENS

8 ft. 

(2.4 m)

  Turn the SENSITIVITY (SENS) control to the mid 

position  and  the  ON-TIME  control  to  the  TEST 
position.

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

Summary of Contents for SL-5309

Page 1: ...e Centers and Electrical Supply Stores Long Bolt This package includes Move ON TIME Switch to 1 5 or 10 minutes Mode Switching Summary Flip switch off for one second then back on TEST AUTO MANUAL MODE ON TIME ON TIME If you get confused while switching modes turn the power off for one minute then back on After the calibration time 1 1 2 min the control will be in the AUTO mode INSTALLATION For eas...

Page 2: ...lation And Relamping When re lamping turn power off and let the fixture cool CAUTION to avoid fire or burn hazards Allow fixture to cool before touching The bulb and fixture operate at high temperatures Keepfixtureatleast2 51mm fromcombustiblemateri als Do not aim at objects closer than 3 feet 1 m Re lamp with type T 300W or less halogen 120 VAC lamp only Rotate the sensor head towards the clamp s...

Page 3: ...rces could cause false triggering Areas where pets or traffic may trigger the control Nearbylarge light coloredobjectsreflectinglightmay trigger the shut off feature Do not point other lights at the sensor 60 ft 18 3 m The control is most sensitive to motion across it Least Sensitive Most Sensitive Motion Sensor Motion Loosen the clamp screw in thesensorballjointandgently rotate the sensor to aim ...

Page 4: ...u may also write to HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Pur chase and Place of Purchase No Service Parts Available for this Product ONE YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights whic...

Page 5: ...ONAMIENTO Se pone en Automático al amanecer ON TIME ON TIME PRUEBA AUTOMATICO INSTALACION Para una fácil instalación escoja una luz con un interruptor de pared Nota Cuando ajuste el brazo hale los alambres para asegurarse de que no se pinchen al unirlos Una el brazo de la lám para de la placa poste rior y asegúrela con el perno largo 10 5 1 TEST 10 5 1 TEST Para MODO MANUAL préndalo 1 segundo APAG...

Page 6: ... los peligros de incendio o quemazón Dejequeelelementoseenfríeantesdetocarlo Labom billa y el elemento funcionan a altas temperaturas Mantenga al elemento por lo menos a 2 Pulg de los materiales combustibles No lo apunte hacia objetos que estén más cerca de 3 pies Cambie sólo con bombillas T halógena de dos clavijas de 120 VCA y de 300W Máx Gire la cabeza del detector hacia la unión del tornillo d...

Page 7: ...lo de la grampa No apriete demasiado el tornillo FijeelperíododeTIEMPOquelaluzdebequedarse prendida cuando detecta movimiento Se lo puede calibrar de 1 5 ó 10 minutos Angulo Máximo de Cobertura Alcance Máximo Lo menos sensible Lo más sensible Detector Movimiento El detector es más sensible al movimiento lateral Movimiento 110 NOTA El detector tiene un período de cerca de 12 minutos de calentamient...

Page 8: ... de 7 30 AM a 4 30 PM CST L V Usted puede también escribir a HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Servicio Técnico Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto GARANTÍA LIMITADA A 1 AÑO Esta es una Garantía Limitada qu...

Page 9: ...soleil FONCTIONNEMENT PRIORITÉ MANUELLE hors circuit pen dant 1 seconde puis à nouveau en circuit Placer l interrupteur ON TIME à 1 5 ou 10 minutes Mettre l interrupteur hors circuit pendant une seconde puis le remettre en circuit Si vous ne savez plus dans quel mode se trouve l appareil couper l alimentation pendant une minute puis la rétablir Après le temps d étalonnage 1 1 2 min la commande rev...

Page 10: ...a vis de terre de la plaque de garde au fil de terre de la boîte de jonction noir noir garniture de joint Le luminaire halogène doit être monté horizontalement 4 Avantderemplacerl ampoule couperl alimentation et laisser refroidir le luminaire Percez les trous néces saires au montage de la plaque arrière à la boîte de jonction CORRECT INCORRECT Puis faire pivoter le détecteur sur 180 de façon que l...

Page 11: ... 110 REMARQUE Le capteur doit se réchauffer 1 1 2 minute avantdepouvoirdétecterlemouvement Lorsque l appareil est mis en circuit ou changé de mode attendre 1 1 2 minute Bas du détecteur ON TIME 10 5 1 TEST MIN MAX SENS ESSAIS ET RÉGLAGES Mettre en circuit le disjoncteur et l interrupteur d éclairage Portée maximale Angle de couverture maximale Le détecteur est moins sensible au mouvement dans sa d...

Page 12: ...ntre 7 h 30 et 16 h 30 HNC du lundi au vendredi Vous pouvez aussi écrire au HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Service technique Lors d un appel au service technique veuillez avoir les renseignements suivants à portée de main numéro du modèle date d achat et endroit de l achat Aucune pièce de rechange n est disponible pour ce produit GARANTIE LIMITÉE DE 1 ...

Reviews: