Drill  out  the  holes  if 
needed  to  mount  the 
backplate to the junction 
box.

  Remove the existing light fixture.

  Strip about 5/8" (16 mm) insulation from the existing 

junction box wiring.

  Route  the  light  control’s  wires  through  the  large 

hole in the gasket.

  Twist the junction box wires and fixture wires together 

as shown. Secure with a wire connector.

For  proper  operation  and  safety,  the  light  fixture 
must be above the sensor.

  Align the light control cover plate and cover plate 

gasket and the junction box. Insert and tighten the 
mounting screws. 

  If not installed on a weatherproof box or if an adaptor 

plate is used, 

caulk the wall plate and mounting 

surface

 with silicone weather sealant.

M

ount

 

the

 L

ight

 C

ontroL

Cover Plate Gasket

The  halogen  light  must  be 
mounted horizontally (+/- 4°).

 

RIGHT 

WRONG

Black

 to 

Black

White

 to 

White

Junction  box  ground  wire  to  green 
ground wire on fixture.

 WARNING: Turn  power  off  at  circuit  breaker 

or fuse.

W

ire

 

the

 L

ight

 C

ontroL

B

uLB

 i

nstaLLation

 a

nd

 r

eLaMping

  When re-lamping, 

turn power off

 and let the fixture 

cool.

CAUTION to avoid fire or burn hazards:

• Allow fixture to cool before touching. The bulb and 

fixture operate at high temperatures.

• Keep fixture at least 2" (51 mm) from combustible materi-

als. Do not aim at objects closer than 3 feet (1 m).

• Re-lamp with type T 300W (or less) halogen 120 

VAC lamp only.

 

Rotate the sensor head towards the clamp screw 
joint.

Clamp Screw

Controls

  Then rotate the sensor head clockwise 180° so 

the controls face down.

Controls

  Remove glass cover and remove the old bulb by 

pushing the bulb towards the right until the left side 
of the bulb is clear of the left socket.

  To insert the new bulb, push the bulb into the right 

socket  so  the  bulb  fits  completely  into  the  left 
socket.

  Check that the bulb is seated properly.

❒ 

Re-install the glass cover.

For under eave installation, the sensor head must 
be rotated

 as shown in the next two steps for proper 

operation and to avoid the risk of electrical shock.

For eave mount only:

If  the  sensor  pops  out  of  the  ball  joint,  loosen  the 
clamp screw and push the sensor back into the ball 
joint. Tighten the clamp screw when done.

Summary of Contents for SL-5309

Page 1: ...e Centers and Electrical Supply Stores Long Bolt This package includes Move ON TIME Switch to 1 5 or 10 minutes Mode Switching Summary Flip switch off for one second then back on TEST AUTO MANUAL MODE ON TIME ON TIME If you get confused while switching modes turn the power off for one minute then back on After the calibration time 1 1 2 min the control will be in the AUTO mode INSTALLATION For eas...

Page 2: ...lation And Relamping When re lamping turn power off and let the fixture cool CAUTION to avoid fire or burn hazards Allow fixture to cool before touching The bulb and fixture operate at high temperatures Keepfixtureatleast2 51mm fromcombustiblemateri als Do not aim at objects closer than 3 feet 1 m Re lamp with type T 300W or less halogen 120 VAC lamp only Rotate the sensor head towards the clamp s...

Page 3: ...rces could cause false triggering Areas where pets or traffic may trigger the control Nearbylarge light coloredobjectsreflectinglightmay trigger the shut off feature Do not point other lights at the sensor 60 ft 18 3 m The control is most sensitive to motion across it Least Sensitive Most Sensitive Motion Sensor Motion Loosen the clamp screw in thesensorballjointandgently rotate the sensor to aim ...

Page 4: ...u may also write to HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Pur chase and Place of Purchase No Service Parts Available for this Product ONE YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights whic...

Page 5: ...ONAMIENTO Se pone en Automático al amanecer ON TIME ON TIME PRUEBA AUTOMATICO INSTALACION Para una fácil instalación escoja una luz con un interruptor de pared Nota Cuando ajuste el brazo hale los alambres para asegurarse de que no se pinchen al unirlos Una el brazo de la lám para de la placa poste rior y asegúrela con el perno largo 10 5 1 TEST 10 5 1 TEST Para MODO MANUAL préndalo 1 segundo APAG...

Page 6: ... los peligros de incendio o quemazón Dejequeelelementoseenfríeantesdetocarlo Labom billa y el elemento funcionan a altas temperaturas Mantenga al elemento por lo menos a 2 Pulg de los materiales combustibles No lo apunte hacia objetos que estén más cerca de 3 pies Cambie sólo con bombillas T halógena de dos clavijas de 120 VCA y de 300W Máx Gire la cabeza del detector hacia la unión del tornillo d...

Page 7: ...lo de la grampa No apriete demasiado el tornillo FijeelperíododeTIEMPOquelaluzdebequedarse prendida cuando detecta movimiento Se lo puede calibrar de 1 5 ó 10 minutos Angulo Máximo de Cobertura Alcance Máximo Lo menos sensible Lo más sensible Detector Movimiento El detector es más sensible al movimiento lateral Movimiento 110 NOTA El detector tiene un período de cerca de 12 minutos de calentamient...

Page 8: ... de 7 30 AM a 4 30 PM CST L V Usted puede también escribir a HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Servicio Técnico Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto GARANTÍA LIMITADA A 1 AÑO Esta es una Garantía Limitada qu...

Page 9: ...soleil FONCTIONNEMENT PRIORITÉ MANUELLE hors circuit pen dant 1 seconde puis à nouveau en circuit Placer l interrupteur ON TIME à 1 5 ou 10 minutes Mettre l interrupteur hors circuit pendant une seconde puis le remettre en circuit Si vous ne savez plus dans quel mode se trouve l appareil couper l alimentation pendant une minute puis la rétablir Après le temps d étalonnage 1 1 2 min la commande rev...

Page 10: ...a vis de terre de la plaque de garde au fil de terre de la boîte de jonction noir noir garniture de joint Le luminaire halogène doit être monté horizontalement 4 Avantderemplacerl ampoule couperl alimentation et laisser refroidir le luminaire Percez les trous néces saires au montage de la plaque arrière à la boîte de jonction CORRECT INCORRECT Puis faire pivoter le détecteur sur 180 de façon que l...

Page 11: ... 110 REMARQUE Le capteur doit se réchauffer 1 1 2 minute avantdepouvoirdétecterlemouvement Lorsque l appareil est mis en circuit ou changé de mode attendre 1 1 2 minute Bas du détecteur ON TIME 10 5 1 TEST MIN MAX SENS ESSAIS ET RÉGLAGES Mettre en circuit le disjoncteur et l interrupteur d éclairage Portée maximale Angle de couverture maximale Le détecteur est moins sensible au mouvement dans sa d...

Page 12: ...ntre 7 h 30 et 16 h 30 HNC du lundi au vendredi Vous pouvez aussi écrire au HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Service technique Lors d un appel au service technique veuillez avoir les renseignements suivants à portée de main numéro du modèle date d achat et endroit de l achat Aucune pièce de rechange n est disponible pour ce produit GARANTIE LIMITÉE DE 1 ...

Reviews: