C. Installing Non-combustible Facing Material
Figure 6.3 Attaching Non-combustible Facing Material
Fire Risk.
• Follow these instructions exactly.
• Facing materials must be installed properly to
prevent fire.
• No materials may be substituted without
authorization by Hearth & Home Technologies.
• Center and attach top board to the framing members
(see Figure 6.3).
• Use fasteners from fastener packet (in manual bag) in
shaded areas (Figure 6.3).
• Use regular sheetrock screws in non-shaded areas (see
Figure 6.3).
APPLY
FASTENERS FROM
FASTENER PACKET
IN SHADED AREAS
WARNING
WARNING!
Fire Risk.
Maintain specified clearances
around the appliance.
DO NOT
notch into the framing
around the appliance spacers.
• Attach the left and right side pieces to the framing
members. (See Figure 6.3).
• Use a wet or dry towel or soft brush to remove dust or
dirt from facing material.
• Apply a non-combustible adhesive to attach tile,
stone or other non-combustible finishing materials per
manufacturer’s instructions.
Figure 6.4 Complete Installation of Non-combustible
Facing Material
A
B
CERONA-36-IFT
in.
43-5/8 50-3/16
mm
1108
1275
CERONA-42-IFT
in.
50-5/8
54-3/8
mm
1286
1381
A
B
NON-COMBUSTIBLE
FACING MATERIAL
1 in.