Heat & Glo • SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT Installation Manual • 2472-980 Rev. Q • 3/20
Combustible Mantels
Non-Combustible Mantel Legs or Wall Projections
Note:
Measurement is taken from top of the
opening, NOT the top of the fireplace.
B. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as specified. Framing closer than the minimums list
-
ed must be constructed entirely of noncombustible materials
(i.e., steel studs, concrete board, etc.)
UNLIMITED
TOP VIEW
5-7/8 IN.
MINIMUM
3 IN.
MINIMUM
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.5 Combustible Mantel Legs or Wall Projections
(Acceptable on one side of opening)
Note
: Clearance from opening
to perpendicular wall.
All measurements are in inches.
Figure 10.6 Non-Combustible Mantel Legs or Wall Projections
(Acceptable on both sides of opening)
Figure 10.2 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
TOP OF HOOD OR FIREPLACE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
3
4
5
12
11
10
9
8
7
6
32
CEILING
1
5 6
7 8
9
10
4
12
11
13
3
Non-Combustible Mantels
Figure 10.3 Minimum Vertical and Maximum Horizontal
Dimensions of Non-Combustibles
TOP OF HOOD OR FIREPLACE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
6
12
11
10
9
8
7
32
CEILING
8
9
10
3/8
12
11
13
All measurements are in inches.
UNLIMITED
TOP VIEW
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
3 IN. MIN.
6 IN MAX.
Note
: Clearance from opening
to perpendicular wall.
Combustible Mantel Legs or Wall Projections
3 FT. MAXIMUM
TOP VIEW
2-7/8 IN.
MINIMUM
1/2 IN.
MINIMUM
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Note
: Clearance from opening
to perpendicular wall.
Figure 10.4 Combustible Mantel Leg or Wall Projection
(Acceptable on both sides of opening)