18
Heat & Glo • SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT Installation Manual • 2472-980 Rev. Q • 3/20
C. Approved Pipe
Approved Pipe - Rigid
This appliance is approved for use with Hearth & Home
Technologies DVP or SLP venting systems. Refer to Sec
-
tion 12.A for vent component information and dimensions.
DO NOT
mix pipe, fittings or joining methods from differ
-
ent manufacturers.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
WARNING! Risk of Fire or Asphyxiation.
This appli-
ance requires a separate vent.
DO NOT
vent to a pipe
serving a separate solid fuel burning appliance.
Approved Pipe - Flex
This appliance is approved for use with Hearth & Home
Technologies SLP-FLEX (6-5/8 in.) and SLP-FLEX7 (7
inch) venting systems.
DO NOT
mix pipe, fittings or joining methods from differ
-
ent manufacturers. SLP-FLEX and SLP-FLEX7
venting cannot be interchanged.
SLP-FLEX (6-5/8 Inch):
venting may be used in any
venting configuration shown in the venting tables provid
-
ed that the horizontal vent length is reduce by 25%.
SLP-FLEX7 (7 Inch-Canada Only):
venting requires
adapter collars to transition from the 6-5/8 in. appliance
starting collar and to the 6-5/8” termination cap. Refer to
installation instructions included with the SLP-FLEX7 col
-
lar adapter (SLP-FLEX7-A). SLP-FLEX7 Series venting
is approved for use in Canada only.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
WARNING! Risk of Fire or Asphyxiation.
This appli-
ance requires a separate vent.
DO NOT
vent to a pipe
serving a separate solid fuel burning appliance.