22
Heat & Glo • SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT Installation Manual • 2472-980 Rev. Q • 3/20
Figure 4.11
One Elbow
Top Vent - Horizontal Termination
V Minimum
H Maximum
All Models
90º Elbow*
1 ft.
305 mm
1/2 ft.*
152 mm
2 ft.
610 mm
1-1/2 ft.*
457 mm
3 ft.
914 mm
2-1/2 ft.*
762 mm
5 ft.
1-1/2 m
3-1/2 ft.
1.1 m
7 ft.
2.1 m
4-1/2 ft.
1.4 m
15 ft.
4.6 m
H
1
Maximum= 15 ft. (4.6 m)
V
1
+ H
1
Maximum= 40 ft. (12.2 m)
* See warning below
Note
: Use SLP Series
components only.
Note
: There MUST be a 25%
reduction in total H when
using flex vent except when
using the simple up and out
installation. See Figure 4.9.
H
1
V
1
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fireplaces, a one foot minimum
vertical vent section is required before installing
first elbow.
WARNING *