50
Heat & Glo • SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT Installation Manual • 2472-980 Rev. Q • 3/20
Figure 8.2 IntelliFire Touch Wiring Diagram
LED’s
LED’s are factory installed. No additional set up or
maintenance is required.
B. Wiring Requirements
IntelliFire Touch
®
Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2, IntelliFire Touch (IPI) Wiring Diagram.
• This appliance is equipped with an IntelliFire control valve
which operates on a 6 volt system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
FLAME
SENSE IGNITER
LED
CONTROL
RF MODULE
VALVE
IFT-RC400
REMOTE
CONTROL
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
RED
6V DC
BATTERY PACK
BLK
RED
(OPTIONAL)
JUMPER
WIRE
APPLIANCE
ON/OFF
CONTROL
BRN
BLK
EMBER LIGHTING
NOT USED FOR SL-3X-IFT, SL-5X-IFT, SL-5XLP-IFT,
SL-7X-IFT, SL-7XLP-IFT, SL-9X-IFT MODELS
MODELS.
FAN
ORANGE
(PILOT)
GREEN
(MAIN)
FLAME
MODULATION
BLK (GROUND)
TO JUNCTION
BOX (110-120 VAC)
TO JUNCTION
BOX (110-120 VAC)
ORANGE
WHITE
PVI-SLP-B
PVLP-SLP
WIRE HARNESS
PVI-WH10
PVI-WH20
PVI-WH40
PVI-WH60
PVI-WH80
PVI-WH100
(OPTIONAL POWER VENT)
ELECTRONIC CONTROL
MODULE (ECM)
AUXILIARY CONTROL
MODULE (ACM)
NOTICE:
Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.