Heat & Glo • GEM-42B • 2096-900 Rev. H • 3/06
29
A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the junction
box for proper operation of the appliance. This appliance
uses an Intellifire ignition system.
Electrical Information
10
NOTE:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with
National Electric Code ANSI/NFPA 70-
latest edition
or the
Canadian Electric Code, CSA C221.1
.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
•
Incorrect wiring will damage millivolt valves.
•
Incorrect wiring will override IPI safety
lockout and may cause explosion.
Optional Accessories Requirements
Wiring for optional accessories should be done now to avoid
reconstruction.
•
This appliance
includes the WSK-MLT wall control. It
requires the installation of a wall switch, to be connected
to this appliance. Please reference the WSK-MLT instruc-
tions for specific installation and operating instructions.
•
Use the wire provided with this product to connect the
wall switch with the receiver control, as outlined in the
instructions for the WSK-MLT control.
•
Keep wire lengths short as possible by removing any
excess wire length.
•
Low voltage and 110 VAC voltage cannot be shared within
the same wall box.
CAUTION
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous op-
eration. Verify proper operation after servicing.
Shock hazard.
• Replace damaged wire with type 105
O
C
rated wire.
• Wire must have high temperature insulation.
WARNING
C. Intellifire Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 10.1.
This appliance is equipped with an Intellifire control valve
which operates on a 3 volt system. This appliance is sup-
plied with a battery pack which requires two D cell batter-
ies (not included).
CAUTION
Battery polarity must be correct or module damage
will occur.