Electrical Connection
Electrical wiring infor mation
A n a d e q u a t e e l e c t r i c a l s u p p l y m u s t b e p r o v i d e d
fo r t h i s u n i t . A l l w i r e c o n n e c t i o n s a n d g r o u n d i n g
m u s t b e d o n e i n a c c o r d a n c e w i t h l o c a l e l e c t r i c a l
codes, or if these codes are not established, then
with the National Electr ical Code, ANSI/NFPA No.
7 0 i n t h e U S , o r w i t h t h e C a n a d i a n E l e c t r i c a l
Code, CAN/CSA C22.1, in Canada.
T h i s u n i t c o m e s e q u i p p e d w i t h t h r e e c o n n e c t i o n
w i r e s i n a f l ex i b l e c o n d u i t . T h e c o n d u i t m u s t b e
r o u t e d a n d p r o p e r l y c o n n e c t e d t o a n a p p r o v e d
o w n e r s u p p l i e d e l e c t r i c a l w a l l j u n c t i o n b o x . A n
a p p r ove d c o n n e c t o r mu s t b e u s e d fo r c o n n e c t i n g
t h e c o n d u i t t o t h e j u n c t i o n b ox . A t h r e e w i r e , 2 -
p o l e , 2 4 0 V 6 0 H z s e r v i c e w i t h m i n i m u m 4 0 A
c i r c u i t p r o t e c t o r m u s t b e p r o v i d e d . T h e r e d a n d
t h e bl a ck w i r e f r o m t h e u n i t a r e t o b e c o n n e c t e d
t o t h e s e r v i c e ( ’ h o t ’ ) w i r e s, a n d t h e gr e e n w i r e i s
to be connected to the ground conductor.
T h e o w n e r s h o u l d m a r k t h e c i r c u i t p r o t e c t o r fo r
the unit and should advise ever ybody who uses or
s e r v i c e s t h e c o o k t o p o n i t s l o c a t i o n , s o t h a t t h e
p o w e r t o t h e u n i t c a n b e d i s c o n n e c t e d w h e n
necessar y.
O n c e t h e u n i t i s p r o p e r l y f i t t e d a n d c o n n e c t e d t o
t h e e l e c t r i c a l p o w e r s u p p l y, t u r n t h e u n i t o n t o
e n s u r e t h a t a l l e l e m e n t s a n d c o n t r o l s a r e
operating well.
N o t e t h a t y o u r u n i t i s d e s i g n e d fo r 2 4 0 V s u p p l y
and the manufacturer, its distr ibutors and dealers
c a n n o t b e h e l d r e s p o n s i b l e f o r a n y u n i t
malfunction due to an inadequate electrical supply
( i n a d e q u a t e c a b l e s i z e , l o w v o l t a g e e t c ) .
F u r t h e r m o r e, i f yo u r r e s i d e n c e h a s o n l y a 2 0 8 V
s u p p l y s y s t e m , a n d i f t h e v o l t a g e f r e q u e n t l y
f l u c t u a t e s , y o u r c o o k t o p m a y n o t f u n c t i o n
properly.
I t i s r e c o m m e n d e d t h a t t h e c o n n e c t i o n t o
electrical supply is done by a qualified electrician.
I f t h e r e i s a n y v i s i b l e p h y s i c a l d a m a g e o n t h e
c o n d u i t a n d t h e w i r e s , t h e u n i t m u s t n o t b e
connected to the mains. A qualified electr ician or
a p p r o v e d s e r v i c e a g e n t s h o u l d b e c a l l e d i n t o
replace the wires and the conduit.
240V
Connect the 3 wires as per the following
color code
RED
BLACK
GREEN
P
h
a
s
e
2
P
h
a
s
e
1
E
a
rt
h
L
L
Hear tland INDUCTION Cooktop electrical Characteristics:
Operating voltage
Total Energy consumption
Connect to
240V~60Hz
8400 W
240V, 60Hz, 2 Pole+G, 40 A (min) supply
(3 conductors #8 AWG)
8