Other Installation Requirements
Exhaust
Cabinet Above
Cabinet Below
3/8"(10mm)
Minimum Clearance Requirements
Cross Section
30" (750mm)
2" (50mm)
Air
Intake
A m i n i mu m ve r t i c a l c l e a ra n c e o f 3 0 " ( 7 5 0 m m ) i s
r e q u i r e d b e t w e e n t h e t o p o f t h e c o o k i n g s u r fa c e
a n d t h e b o t t o m o f a n y u n p r o t e c t e d c o m b u s t i b l e
material, such as cabinets, wooden trim etc.
I n t h e b a c k , l e a v e a m i n i m u m o f 3 / 8 " ( 1 0 m m )
b e t w e e n t h e c o o k t o p e d g e a n d a d j a c e n t ve r t i c a l
s u r fa c e s ( b a c k s p l a s h , w a l l , h i g h c a b i n e t s e t c . ) .
T h i s s p a c e i s n e e d e d f o r t h e u n i t t o b r e a t h
properly.
I f a d o w n d r a f t v e n t i l a t i o n s y s t e m i s u s e d , a
m i n i mu m o f 1 / 4 " ( 6 m m ) o f c l e a ra n c e i s r e q u i r e d
b e t w e e m t h e r e a r e d g e o f t h e c o o k t o p a n d t h e
downdraft snorkel.
L e ave a m i n i m u m o f 2 " ( 5 0 m m ) u n d e r n e a t h t h e
unit for the air intake.
D u r i n g c o o k i n g , b u i l t - i n fa n s i n s i d e t h e c o o k t o p
w i l l o p e r a t e c o n s t a n t l y t o k e e p t h e i n t e r n a l
c o m p o n e n t s c o o l . T h e a i r i n t a k e s a r e o n t h e
b o t t o m o f t h e c o o k t o p b o x , a n d t h e w a r m a i r
ex h a u s t s a r e l o c a t e d o n t h e b a c k o f t h e r i m , a s
shown on the schematic. If air intake or exhaust is
o b s t r u c t e d , c o o k t o p s a fe t i e s w i l l e i t h e r d i m i n i s h
the power output or shut down the unit.
W e s u g g e s t t h a t y o u s h o u l d p e r i o d i c a l l y c h e c k
t h a t t h e r e a r e n o o b j e c t s ( d u s t , p a p e r e t c . ) w h i c h
c o u l d o b s t r u c t t h e a i r i n l e t u n d e r yo u r i n d u c t i o n
c o o k t o p . A l t h o u g h i n d u c t i o n - c o o k t o p h e a t
r e j e c t i o n i s m i n i m a l a n d t h e u n i t d o e s n o t c r e a t e
a n y f u m e s i n o p e r a t i o n , s u c h u n i t m u s t b e
i n s t a l l e d u n d e r n e a t h a p r o p e r l y s i ze d ve n t i l a t i o n
h o o d fo r ex h a u s t i n g a ny s m e l l , va p o r a n d s m o ke
c r e a t e d b y c o o k i n g i t s e l f . A l s o , a p r o p e r
downdraft system can be used for ventilation
Never glue, silicone or wedge the unit inside its cut-out.
The unit must be installed such that it can be pulled without difficulty out of the cut-out for
ser vicing or cleaning.
The unit must not be installed above a washing machine, a refrigerator or a deep-freezer box.
To eliminate the risk of bur ns or fire by reaching over heated surface units, cabinet storage
space located above the surface units should be avoided.
Your cooktop must always breath adequately. Make sure that the air inlet and its exhaust are
not obstructed
7