HearthStone
Quality Home Heating Products Inc
®
Bennington Model 8350
21
BREAKS IN THE VENTING SYSTEM:
An unsealed
clean-out door at the bottom of the chimney, leaky
stovepipe joints, a poor stovepipe-to-thimble connection,
or a leaky chimney may cause inadequate draft.
SEASONAL FACTORS:
Early fall and late spring are
generally difficult seasons in which to establish proper
drafts. The colder the outside air (relative to room
temperatures), the stronger the draft.
Operating the Stove
There are days when a draft is not easily established. As
outlined above, seasonal factors or a cold chimney may be
the cause. Try starting the fire by using small kindling
and fuel to obtain a quick, hot fire. Tend the fire
frequently with small fuel until the chimney is hot and the
draft is well established.
T
ROUBLESHOOTING
G
UIDE
PROBLEM
POSSIBLE CAUSE
SOLUTIONS
STOVE SMOKES
Operating Technique
Fully open the primary air control one minute before opening doors.
Cold Chimney
Preheat the chimney when first starting a fire.
Blocked Chimney
Examine the chimney and stovepipe for blockage or creosote
accumulations.
Oversized Chimney
Reline the chimney to the appropriate diameter
Undersized Chimney
Install a draft inducer or replace the chimney.
Chimney Too Short
Lengthen the chimney.
Air Infiltration Into The
Chimney
Seal chimney connections and openings in clean-out doors.
More Than One Appliance
Connected to the Flue
Disconnect all other appliances and seal openings.
BACK-PUFFING OR
GAS EXPLOSIONS
Operating Technique
Fully open the primary air control one minute before opening the
door and keep it fully open for a few minutes after reloading.
Extra Low Burn Rate
Burn the stove at a higher burn rate.
Chimney Down-draft
Install a chimney cap.
Excessive Ash Build-up
Empty ash pan more frequently.
UNCONTROLLED
OR SHORT BURN
Unsealed or Open Door
Close the door tightly or replace the gaskets.
Excessive Draft
Check the installation. Operate at LOW BURN. Install stovepipe
damper.
Deteriorated Cement Seals
Reseal the stove with furnace cement.
Extra Long Chimney
Shorten the chimney. Install stovepipe damper.
Oversized Chimney
Reline the chimney to the proper diameter.
High Winds or Hilltop
Location:
Install a chimney cap.
Excessive Draft
Draft in excess of 0.1 wc should be corrected with a stovepipe
damper
INSUFFICIENT HEAT
Poor Quality or Green
Wood
Use only air-dried wood, preferably dried at least one year.
Low Burn Rate
Operate the stove at a higher burn rate.
Air Insulated Chimney
Replace with a pre-fabricated insulated chimney system or a
properly sized masonry chimn ey.
Cold Exterior Chimney
Reline or insulate the chimney.
Leaky Stovepipe or
Chimney
Check the installation.
Too Much Heat Loss From
House
Caulk windows, seal openings in home.
BLISTERING OF
ENAMEL CASTING
Operating Technique
Do not over-fire the stove. Monitor stove temperatures. Use
seasoned wood only.
Excessive Draft
Check the DRAFT. A damper may be required. Operate the stove at
a LOW BURN range.