HearthStone Bennington 8350 Owner'S Manual Download Page 22

HearthStone 

Quality Home Heating Products Inc 

®  

                                                                                                                                                                 Bennington  Model 8350            

21 

BREAKS IN THE VENTING SYSTEM:

  An unsealed 

clean-out door at the bottom of the chimney, leaky 
stovepipe joints, a poor stovepipe-to-thimble connection, 
or a leaky chimney may cause inadequate draft. 
 

SEASONAL FACTORS:

 Early fall and late spring are 

generally difficult seasons in which to establish proper 
drafts.  The colder the outside air (relative to room 
temperatures), the stronger the draft.   

Operating the Stove  

There are days when a draft is not easily established.  As 
outlined above, seasonal factors or a cold chimney may be 
the cause.  Try starting the fire by using small kindling 
and fuel to obtain a quick, hot fire.  Tend the fire 
frequently with small fuel until the chimney is hot and the 
draft is well established.

T

ROUBLESHOOTING 

G

UIDE 

 

PROBLEM  

POSSIBLE CAUSE 

SOLUTIONS 

STOVE SMOKES 

Operating Technique 

Fully open the primary air control one minute before opening doors. 

 

Cold Chimney 

Preheat the chimney when first starting a fire. 

 

Blocked Chimney 

Examine the chimney and stovepipe for blockage or creosote 
accumulations. 

 

Oversized Chimney 

Reline the chimney to the appropriate diameter 

 

Undersized Chimney 

Install a draft inducer or replace the chimney. 

 

Chimney Too Short 

Lengthen the chimney. 

 

Air Infiltration Into The 
Chimney 

Seal chimney connections and openings in clean-out doors. 

 

More Than One Appliance 
Connected to the Flue 

Disconnect all other appliances and seal openings. 

BACK-PUFFING OR 
GAS EXPLOSIONS 

Operating Technique 

Fully open the primary air control one minute before opening the 
door and keep it fully open for a few minutes after reloading. 

 

Extra Low Burn Rate 

Burn the stove at a higher burn rate. 

 

Chimney Down-draft 

Install a chimney cap. 

 

Excessive Ash Build-up 

Empty ash pan more frequently. 

UNCONTROLLED 
OR SHORT BURN 

Unsealed or Open Door 

Close the door tightly or replace the gaskets. 

 

Excessive Draft 

Check the installation. Operate at LOW BURN. Install stovepipe 
damper. 

 

Deteriorated Cement Seals  

Reseal the stove with furnace cement. 

 

Extra Long Chimney 

Shorten the chimney.  Install stovepipe damper. 

 

Oversized Chimney 

Reline the chimney to the proper diameter. 

 

High Winds or Hilltop 
Location: 

Install a chimney cap. 
 

 

Excessive Draft 

Draft in excess of 0.1 wc should be corrected with a stovepipe 
damper 

INSUFFICIENT HEAT 

Poor Quality or Green 
Wood 

Use only air-dried wood, preferably dried at least one year. 

 

Low Burn Rate 

Operate the stove at a higher burn rate. 

 

Air Insulated Chimney 

Replace with a pre-fabricated insulated chimney system or a 
properly sized masonry chimn ey. 

 

Cold Exterior Chimney 

Reline or insulate the chimney. 

 

Leaky Stovepipe or 
Chimney 

Check the installation. 

 

Too Much Heat Loss From 
House 

Caulk windows, seal openings in home. 

BLISTERING OF 
ENAMEL CASTING 

Operating Technique 

Do not over-fire the stove.  Monitor stove temperatures. Use 
seasoned wood only. 

 

Excessive Draft 

Check the DRAFT. A damper may be required.  Operate the stove at 
a LOW BURN range. 

 
 

Summary of Contents for Bennington 8350

Page 1: ...fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Bennington Model...

Page 2: ...mponents of a Venting System 10 Installing a Venting System 11 CONNECTING YOUR WOOD STOVE 11 Connecting to a Prefabricated Metal Chimney 11 Connection To A Masonry Chimney 13 INSTALLING IN A MOBILE HO...

Page 3: ...eilings hearth and other combustible surfaces This will help reduce the risk of fire Failure to follow these instructions can result in property damage bodily injury and even death Locate your stove i...

Page 4: ...d and the ash door closed tightly q Inspect the stovepipe chimney connector and chimney as recommended q Be sure the removable ash lip is in place while using the stove If the ash lip is not installed...

Page 5: ...ct all door gasket material and replace if worn frayed cracked or extremely hard EMERGENCY PROCEDURES If you have a stovepipe or chimney fire follow these instructions 1 If the fire is too threatening...

Page 6: ...efficiency combustion you desire This new technology will not corrode rust dissolve or lose its strength however it is vulnerable to puncture or cracking due to rough handling PLEASE EXERCISE CARE WH...

Page 7: ...om 15 to 36 lbs per cubic foot depending on type of wood moisture content packing density and other factors As a constant for comparison and test purposes we are assuming 20 lbs of seasoned hardwood p...

Page 8: ...e Protection Agency NFPA approved wall protection system Please refer to NFPA 211 for specifications and complete details You can obtain this information directly from NFPA National Fire Protection Ag...

Page 9: ...kness R value Gypsum or plaster board1 0 45 Wallboard Wonderboard or Durock1 0 20 Ceramic board Fiberfrax or Micor 1 1 10 Nominal solid clay brick1 1 0 20 Ceramic wall or floor tile1 0 01 Mineral wool...

Page 10: ...EARANCES TO COMBUSTIBLES from closest point of stove Unprotected Surfaces Protected Surfaces NFPA 211 Parallel Corner Parallel Corner Installation type Side Rear Side Rear single wall connector R 18 i...

Page 11: ...y connector shall not pass through floor or ceiling nor any attic or roof space closet or similar concealed space Where passage through a wall or partition of combustible construction is desired the i...

Page 12: ...2 3 mm x 13 mm sheet metal screws into the holes pre drilled in the flue collar Leaving off the screws can cause joints to separate from the vibration that results from a creosote chimney fire You can...

Page 13: ...then up the outside of the residence Whenever possible choose an interior chimney An interior chimney heats up more quickly and retains its heat thus promotes a better draft and dis courages the forma...

Page 14: ...size for best results An oversized flue will contribute to the accumulation of creosote Use the following checklist to ensure that your masonry chimney meets these minimum requirements Chimney wall co...

Page 15: ...9196N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap storm collar Adjustable vented flashing 0 12 6 12 Two 24 Dura Plus chimney pipes 24 support box with built in starter s...

Page 16: ...OOR FRONT DOOR HANDLE HOLDER then close the right door tightly and lower the handle to the 4 o clock position Pull on the door handle to make sure it is properly latched then remove the handle Your ha...

Page 17: ...s for stacking an old Vermonter said The spaces between the logs should be large enough for a mouse to get through but not for the cat that s chasing it Firewood should not be stored within the stove...

Page 18: ...per Kindling should be approximately ten pieces 1 2 13 mm in diameter and 10 to 18 254 to 457 mm long 2 Fully open the primary air control by pushing the lever down 3 Light the paper under the kindlin...

Page 19: ...shes as described below Re insert the ash pan by pushing it in all the way Be sure that the ash pan has been pushed firmly into place Alternately the ashes can be removed with a shovel through the sid...

Page 20: ...ately to fully press the gasket into place and assure a positive seal We require the use of the following gaskets GLASS 60 1524 mm Length 3 4 19 mm Wide Adhesive Backed Black Tape DOOR 60 1524 mm Leng...

Page 21: ...sulated the number and size of glass windows the tightness of outside doors and the construction or style of your house vaulted ceilings or other open spaces which collect large percentages of heat ce...

Page 22: ...e Connected to the Flue Disconnect all other appliances and seal openings BACK PUFFING OR GAS EXPLOSIONS Operating Technique Fully open the primary air control one minute before opening the door and k...

Page 23: ...45 FRONT 5350 071 SECONDARY AIR TUBE 1 2310 548 AIR CONTROL HANDLE 5350 072 SECONDARY AIR TUBE 2 2310 550 ASH DOOR 5350 073 SECONDARY AIR TUBE 3 2310 560 ASH LIP 5350 012 ASH DOOR HINGE L 2310 565 RIG...

Page 24: ...HearthStone Quality Home Heating Products Inc Bennington Model 8350 23 SAFETY LABEL...

Page 25: ...ponents electrical components and other components or accessories used in conjunction with the installation of the Woodstove not manufactured or supplied by HearthStone against breakage or malfunction...

Page 26: ...tone or a Dealer or allow a Dealer to make a service call at the place where the Woodstove is located In the event the Original Purchaser refuses to allow a Dealer to make a service call HearthStone o...