HearthStone
Quality Home Heating Products Inc
®
Bennington Model 8350
9
SIDE
VIEW
FRONT
VIEW
ALCOVE CLEARANCE TO COMBUSTIBLES
C
LEARANCES
T
O
C
OMBUSTIBLES
* * * * * * * *
Please use this section to plan the layout for your
stove. Consider clearance of
pipe
to combustibles
and
stove
to combustibles. More specifics on
installation follow.
* * * * * * * *
You must follow minimum clearances for the Bennington
stove to combustibles such as walls and ceilings. You may
reduce the general clearances if installing the stove near
Protected Surfaces
(see ”
CLEARANCES TO NFPA 211
PROTECTED SURFACES
” below and following
diagrams).
FREESTANDING MINIMUM CLEARANCES TO COMBUSTIBLES
(from closest point of stove)
Unprotected Surfaces
Protected Surfaces (NFPA 211)
Parallel
Corner
Parallel
Corner
Installation type
Side
Rear
Side
Rear
single wall connector.
* R=18 in. (381 mm) 18 in.
13 in.
6 in.
9 in.
7 in.
L=12 in. (305 mm)
(460 mm)
(330 mm)
(150 mm)
(230-mm)
(180-mm)
double wall connector.
* R=18 in. (381 mm) 16 in.
12 in.
6 in.
9 in.
7 in.
L=12 in. (305 mm)
(405-mm)
(305-mm)
(150 mm)
(230-mm)
(180-mm)
ALLOWABLE ALCOVE DIMENSIONS
Unprotected Surfaces
Protected Surfaces (NFPA 211)
Min.
Width
Max.
Depth
Min. Height
(stove to ceiling above.)
Min.
Width
Max.
Depth
Min. Height
(stove to ceiling above.)
58 in.
38 in.
48 in.
43 in.
48-in.
24 in.
(1475 mm)
(965 mm)
(1220 mm)
(1090 mm)
(1220 mm) (610 mm)
*With Kit #93-70500(Side Door Lock Kit) left side clearances can be used for the right side.
PARALLEL
CORNER
STOVE CLEARANCE TO COMBUSTIBLES