6.3.9 INSTALLATION OF A COMBUSTIBLE SHELF
A combustible shelf with a depth of 6" (152 mm)
(C)
can be installed at least 58" (1,47 m)
(B)
from the
base of the fireplace
.
Different shelf sizes are listed in the following table.
For a shelf dimension that does not appear in the table, add
52" (1,32 m) to the depth of the shelf to find the safe
position of the shelf. The height
(A) should always be 80" (2.03 m) from the base of the
fireplace.
6.3.10 HEAT SHIELD FOR COMBUSTIBLE SHELF
It is possible to reduce the minimum height required between the floor and a combustible shelf by installing
an optional heat shield. The chart below indicates shelf height and depth with a heat shield.
6.3.11
INSTALLATION OF A NONCOMBUSTIBLE SHELF
It is possible to install a non-combustible shelf above the fireplace. It must be installed at least 48" (1,22 m)
from the base of the fireplace, regardless of the depth of the shelf.
WARNING:
The shelf will be hot. Do not put combustible materials on the shelf
POSITIONING AND DEPTH OF THE
THE SHELF WITH HEAT SHIELD
B
C
50" (1,27 m)
6" (152 mm)
52" (1,32 m)
8" (203 mm)
54" (1,37 m)
10" (254 mm)
56" (1,42 m)
12" (305 mm)
POSITIONING AND
DEPTH OF THE
THE SHELF
B
C
58" (1,47 m)
6" (152 mm)
60" (1,52 m)
8" (203 mm)
62" (1,58 m)
10" (254 mm)
64" (1,63 m)
12" (305 mm)