Frequently Asked Questions/Troubleshooting 

(continued)

Symptom

Possible Cause

Corrective Action

The flame height setting on the 

IFT-RC400 does not appear to 

be functioning properly.

Stepper motor is not connected.

Check if the 4 pin wiring harness from the stepper motor is 

connected to the IFT-ECM.

Appliance lights not working.

Ember/backlighting malfunction.

Using an RMS voltage meter, check the voltage coming out of 

the lights port on the IFT-ACM when the lights are set to highest 

level on the IFT-RC400. If the voltage measured is close to 120V 

AC then power down the appliance and install a new light kit and 

verify if the issue has been resolved.

Fuse in IFT-ACM is blown.

Using an RMS voltage meter, check the voltage coming out of the 

lights port on the IFT-ACM when the lights are set to highest level 

on the IFT-RC400. If voltage measured is closer to zero, then 

replace the IFT-ACM itself.

IFT-ACM is not responding to IFT-

RC400.

Follow steps listed in the second symptom.

Lights are not plugged into IFT-

ACM.

Check wiring and connections.

LED controller is not functioning.

Some appliances come with an LED controller that plugs into the 

Lights port on the IFT-ACM. Verify its wiring and that it is function-

ing and if not replace it and verify if the problem is resolved.

IFT-RC400 displays the following 

message on -screen:  Sorry your 

appliance did not start.  Try again 

by pressing Flame On.

No gas to appliance.    

Accumulation of air in gas line 

from extended period of appliance 

inactivity.  Gas control system 

failure.

Verify that appliance has power and gas.  Verify that the appli-

ance  accepts  flame  ON  commands  with  an  audible  beep,  and 

successfully turns flame on within 90 seconds.  If this failure per

-

sists, contact dealer for service.

ODS Error

Low room oxygen available

Check fresh air accessibility to room.

ODS sensor unit faulty

Replace ODS sensor unit.

Power Vent Error

Faulty Power Vent Blower

Replace Power Vent Blower.

Vacuum Switch or wire 

connection faulty

Check wire and vacuum switch continuity with a digital volt-

meter.

Vacuum switch negative air 

pressure chatter

Change position of vacuum switch or reduce wind disturbance 

with baffle.

Pilot Flame Error

Flame sense rod or wire shorted 

to DC ground (chassis ground).

Locate short and repair.

Faulty pilot assembly

Replace pilot assembly.

Flame sense wire disconnected

Verify Flame sense wire connected.

Hard Lockout Error

Verify hard code lockout (RC400 

error condition described, and 

red/green LED flash condition on 

the IFT-ECM)

Your appliance has been safely disabled.  Please contact your 

dealer for service.

Summary of Contents for 2564-110

Page 1: ...e For best results keep your remote control away from direct radiant heat from the appliance adjacent windows and doors HVAC vents and direct sunlight To use the thermostat function access the main menu screen on your remote and select thermostat Next select your desired set temperature and press SET to confirm the setting The actual room temperature RT measured by your remote control will be disp...

Page 2: ...n appliance is on or off RGB Lights If your appliance is equipped with the RGB lights you can use this function to adjust the desired intensity when appliance is on or off You will also be able to select one of the seven colors or select a scrolling color spectrum of the seven colors Heat Management HM1 If your appliance is a Primo or has Smart Wall option and you are using the Heat Zone option it...

Page 3: ...sory on some products and an option on others When a Power Vent is detected a pre purge of 120 seconds is automatically required During this time the power icon is temporarily replaced with 2min 90s 60s and 30s denoting the countdown until the appliance turns on All other functions except for TURN FLAME OFF are disabled during this time The Power Vent is always ON when the flame is ON When the fla...

Page 4: ... that appliance battery backup is fitted with new batteries After taking these actions communication can be re established by pressing the screen to activate the remote control It may take several minutes for remote control to re establish pairing Sorry your appliance did not start Try again by pressing Flame On Your appliance did not start during the last Flame On command Verify that you have pow...

Page 5: ...e maintenance reminder Tap Main Menu to return to the main menu Replace Remote Batteries Your remote batteries are low Recommend immediate replacement before using remote to control appliance 1 Set the RC400 face down on flat surface when install ing batteries DO NOT touch the screen during bat tery installation or removal 2 Remove the battery cover from the back of the IFT RC400 and install the f...

Page 6: ...C400 acts as the room tempera ture sensor when in thermostat mode IFT RC400 is placed in the path of an air draft or vent Move the IFT RC400 away from the direct path of air flow The IFT RC400 acts as the thermostat room temperature sen sor Flame Modulation The IFT system is designed to automatically adjust the flame intensity based on the difference between the desired room temperature and actual...

Page 7: ...and master reset is on if equipped Power Outage Check power to appliance or if the IFT ECM battery backup is being used install four 4 new AA batteries in backup IFT ECM Mode Verify selector switch in Remote mode IFT ECM Power Verify the IFT ECM connected to AC adapter and AC adapter is plugged into the Junction Box IFT ECM no longer paired to RC400 Follow instructions on pairing IFT RC400 to the ...

Page 8: ...ort on the IFT ACM Verify its wiring and that it is function ing and if not replace it and verify if the problem is resolved IFT RC400 displays the following message on screen Sorry your appliance did not start Try again by pressing Flame On No gas to appliance Accumulation of air in gas line from extended period of appliance inactivity Gas control system failure Verify that appliance has power an...

Page 9: ...ty responsible for compliance could void the user s authority to operate the equipment Canada The IFT RC400 is certified for use in Canada under Industry Canada IC Radio Standards Specification RSS This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any in...

Reviews: